Miele DA 424-4 Betriebs- und Installationshandbuch - Seite 27

Blättern Sie online oder laden Sie pdf Betriebs- und Installationshandbuch für Lüftungshaube Miele DA 424-4 herunter. Miele DA 424-4 40 Seiten. Cooker

Miele DA 424-4 Betriebs- und Installationshandbuch
1) Cut-out for feeding through the
exhaust ducting, the mains cable and,
with ...EXT models, the connection
cable to the external motor
In recirculation mode, only the mains
cable is required.
Exhaust connection C 150 mm (not
needed for recirculation mode)
The exhaust connection in the ceiling
plate is not fixed in the middle which
means that the hood can also be
installed where the exhaust cut-out in
the ceiling is not centrally positioned
over the hob. There is a max. margin of
30 mm in any direction.
Appliance dimensions
Safety distance between hob and
cooker hood
The minimum safety distances
between the top of a cooker or hob
and the bottom of the cooker hood
are as follows, unless a greater
distance is specified by the
manufacturer of your cooking
appliance:
550 mm
above electric hobs and
cookers,
650 mm
above an open grill or
deep fat fryer,
650 mm
above gas hobs and
cookers.
If this cooker hood is installed above
a Miele Wok CS 1028 CombiSet
appliance, a minimum safety
distance of 760 mm must be
maintained between the burner and
the lower edge of the cooker hood.
See "Warning and Safety" instructions
for further information.
– A distance of 650 mm above the hob
may be preferable to give more
working space.
27