Allmatic INVERTER COMPACT Anleitung - Seite 14

Blättern Sie online oder laden Sie pdf Anleitung für Garagentoröffner Allmatic INVERTER COMPACT herunter. Allmatic INVERTER COMPACT 20 Seiten.

5. Preliminary checks
The preliminary checks must be carried out only by professionals and by paying maximum attention. The correct wiring of the motor and the limit
switches is very important for the correct functioning of the automation.
Unlock the motor and supply the system with power only
1
after controlling the wiring connections and checking the
absence of short circuits
Manually bring the gate to a total opening position and
2
check the status of led LS.OP.
Manually bring the gate to a total closing position and
3
check the status of led LS.OP.
Manually bring the gate to the middle of the run and then
lock the motor.
Enter the parameter Manual Movement of MENU B and
4
command the closure of the gate.
WARNING: pay attention with the moving gate!
Enter the parameter Manual Movement of MENU B and
command the opening of the gate.
5
WARNING: pay attention with the moving gate!
Once all above operations are successfully terminated,
6
close the automation and lock the motor.
Fig. 1 - 2
WARNING! Before starting the motor, check the status of the input LEDs considering that all the normally closed (NC)
inputs must have the corresponding LED on (Fig. 1).
If necessary, position the dip switches related to the safety devices in the ON position. After installation, move the DIP to OFF and check
that the safety devices are working properly.
6. Manual motion (Menu B - Manual movement)
This operation must be carried-out only by qualified personnel and by paying maximum attention. The manual motion is an operation planned only for
the phase of installation; it allows to move the gate at a limited speed in both directions.
14 / 20
Check the status of the LEDs input by considering
that all normally closed (NC) inputs must have their
corresponding led alighted.
Led LS.OP is off. Correct functioning
Led LS.OP is on, but led LS.CL is off; check the
connection of the limit switches.
Led LS.CL is off. Correct functioning.
Led LS.CL is on, but led LS.OP is off; check the
connection of the limit switches
The motor starts to move. Watch its sense of rotation:
If the gate opens, then stop the manual motion,
disconnect the system from the power and reverse the
motor connections. Then try again.
If the gate closes, then stop the manual motion and go to
the following phase
The motor starts to move. Watch its sense of rotation:
If the gate closes, then stop the manual motion,
disconnect the system from the power and reverse the
motor connections. Then try again.
If the gate opens, then stop the manual motion and go to
the following phase