Miele DDF 150 Installationsanleitung Handbuch - Seite 12

Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Lüftungshaube Miele DDF 150 herunter. Miele DDF 150 28 Seiten. External motor roof installation
Auch für Miele DDF 150: Betriebs- und Installationshandbuch (24 seiten), Betriebs- und Installationsanleitung (28 seiten)

Miele DDF 150 Installationsanleitung Handbuch
Installation
 Make a  185 mm hole in the wall.
 Push the telescopic wall pipe into the
hole so that it is sitting flush.
The telescopic wall pipe will make it
easier to feed the control cable and
the flexible ducting through later on.
 Position the motor unit bracket on the
outside wall. The control cable
connection must be at the bottom.
 Mark the position of the 3 holes to be
drilled.
 Drill three 8 mm  holes and insert
S8 plugs in the holes.
12
 Connect the 3 mountings through the
fixing holes in the motor unit bracket
as illustrated.
 Position the bracket onto the outside
wall again and feed the control cable
with the six-pole connectors through
the telescopic wall pipe into the
house.
 If equipotential bonding is required,
pull the earth cable through the hole
provided in the motor unit bracket.
Equipotential bonding is required if
the control cable is to be extended
by more than the length of the
extension cable supplied (see
"Electrical connection").