Auch für HP 124708-001 - ProLiant Cluster - 1850: Handbuch zur Umsetzung (35 seiten), Handbuch zur Fehlervermeidung (12 seiten), Technisches Weißbuch (12 seiten), Firmware-Aktualisierung (9 seiten), Übersicht (20 seiten), Einführung Handbuch (22 seiten), Handbuch zur Fehlersuche (18 seiten), Handbuch zur Umsetzung (11 seiten), Installationshandbuch (2 seiten)

HP 124708-001 - ProLiant Cluster - 1850 Handbuch zur Umsetzung

Windows Server 2008 ProLiant Support Pack (PSP)

Table A-2 provides a list of the known issues with installing the PSP.
Table A-2. Known issues with the PSP
Issue
Details
The G5 NIC drivers are not found on the Windows Server 2008 media.
Issue 1
Description
The drivers were not available at the time of submission for inclusion in the Windows
Server 2008 media.
Workaround
Fixed in the G5 NIC drivers available on Windows Server 2008 media. Latest driver
is on the PSP Version 8.00.
Issue 2
HP StorageWorks Fibre Channel Array Notification Driver component shows update not required, if a
supported MSA controller is not found behind a Fibre Channel HBA.
Description
The installation result states that "Not updated - already current" and the installation
log states that " the required hardware is not present......Installation will not continue."
Workaround
A fix for this issue is targeted for a future release of the PSP.
Issue 3
The System Management Home (SMH) page does not run properly under Windows Server 2008.
Description
The SNMP settings have not been configured.
Workaround Go to Services/SNMP and configure both the community string and access rights of
read/create.
Issue 4
The NIC driver for the CP6316 NIC fails to install.
Description
The NIC driver for the CP6316 NIC fails to install.