Fault messages
"Programme sequence or check lights" come
on or flash to indicate a fault or interruption.
The "Gas heating" indicator light goes out on
dryers with gas heating.
Heating
(flashes)
Safety period
(flashes)
Venting
Check fluff filter
(lights up)
The messages are:
"Heating"
Fault in the heating system.
Action: Please inform the Service department
"Safety period"
The maximum running time of the drying pro-
gramme was exceeded because the residual
moisture at the start of the programme was
too high.
Action: Where the residual moisture was too
high start the drying programme again.
If the fault message occurs again please call
the Service department.
"Venting" (without function)
"Check fluff filter"
The fluff filter is clogged.
Action: Clean the fluff filter at the end of the
programme.
Note:
The "Drying", "Cool air" and "Anti-crease" indi-
cator lights flash if there is a power cut or if a
programme has been interrupted (e.g. when a
door has been opened and shut). They are
not indicative of a fault. The lights will stop
flashing when the "Start" button is pressed.
This only applies to gas heated machines
"Gas heating"
The "Gas heating" indicator light goes out and
the dryer switches itself off after approx. 7
minutes, when
– The site gas supply to the machine is inter-
– an ignition fault occurs after the start of a
Gas heating
(goes out)
– The venting duct is blocked or badly re-
– The gas connection pressure is too low
If the fault is still present after these measures
have been taken, it is essential to call a Miele
authorised service technician to deal with the
fault.
9
rupted (e.g. gas stop valve has not been
opened).
Action: Open the gas stop valve.
programme.
Action: To restore operation switch the ma-
chine off and then on again, and press the
"Start" button.
stricted.
Action: Check the venting duct and clean if
necessary.
(there may be a drop in pressure in the gas
supply network).
Action: Inform your gas supplier.