Miele T 6351 Betriebsanleitung
Notes
Reprogramming possibilities
Programme
Q
alterations
Reversing time*
in the Cottons
Programmes 1 to 6
and Timed drying
programmes 10 & 11
Reversing off /
Pause interval
in Cottons
programmes 1 to 6
and Timed drying
programmes 10 & 11
Residual moisture/
Prog. selection with the
Selector switch
Fan and heating
in pause times
Cooling down temperature
Vented air to
Reversing time*
in the Minimum iron
programmes 7 to 9
Reversing off/
Pause interval
in Minimum iron
programmes 7 to 9
without heating
Programme 10
with heating
followed by Cooling down
Programme 11
Additional display
during operation
Programmable residual moisture values
Programme
1
2
A
3
4
5
6
7
B
8
9
The stored residual moisture values for the individual programmes are shown in the additional display after the selector is
pressed. The sequence of the displayed residual moisture values for the programmes is as follows:
B
9
B
8
B
7
A
6
/
,
/
,
/
,
/
Position of the
Programme
Standard
selector switch
1 minute and
1
27 seconds
3
2
seconds
A
see chart
3
"Programmable
residual
moisture"
4
1
5
50
1 minute
6
27 seconds
3
7
seconds
B
15
8
minutes
20
9
minutes
C 0
0
!
T 6251 / T 6351
Options
Standard
Adjustable
- 4 %
- 3 % or - 5 %
- 2 %
- 1 or 0%
3 %
1 % or 5 %
13 %
8 % or 16 %
20 %
18 % or 22 %
26 %
24 % or 30 %
- 2 %
0 % or - 3 %
2 %
1 % or 4 %
8 %
5 % or 10 %
A
5
A
4
,
/
,
/
Options
TR
Bedd-
Adjustable
ing
25
25
20 seconds
secs
secs
to
2 minutes
10
0 (Off)
secs
or
2 to 10
seconds
0
0
0 or 1
o
C
40 °C
30 to 60
55
20 seconds
secs
to
2 minutes
0 (Off)
or
2 to 10
seconds
3 minutes
to
1 hour
3
3 minutes
mins
to
3 hours
2
0, 1 or 2
T 6551 / T 6751
Options
Standard
Adjustable
- 4 %
- 3 % or - 5 %
- 2 %
- 1 or 0%
3 %
1 % or 5 %
16 %
8 % or 13 %
22 %
18 % or 20 %
30 %
24 % or 26 %
- 2 %
0 % or - 3 %
2 %
1 % or 4 %
8 %
5 % or 10 %
19
Notes
*)Drum reverses to the left
and to the right in pro-
grammed timed intervals
Call up the residual moisture
values to be changed with
the selector switch and alter
with the start button.
1 = On
0 = Off
o
C
add to this cooling down
time to a cool temperature
o
of 50
C (Standard value).
0 = Residual moisture
(temperature display for
5 secs, after the selector
button is pressed)
1 = temperature only
2 = residual moisture only
Programme position is not
occupied.
Notes
A
3
A
2
/
,
/
«M.-Nr.04989220/02 - GB - »
Enter
programmed
options here
Enter
programmed
options here
A