Installing the appliance
Fitting the plinth
To ensure trouble-free operation of
the appliance it is essential to fit the
original Miele ventilation grille.
^ Remove ventilation grille b by
pressing down the two lugs a and
simultaneously pulling the grille
forwards.
The plinth facing c can be fitted
without being altered in the following
situations:
It can be fitted unchanged if the
following dimensions are present:
Building-under
height
A
[mm]
820
870
36
Plinth facing
height
b
[mm]
100
150
The height of the plinth facing has to
be altered in the following
circumtances:
If the building-under height A = 820
mm and the plinth facing height b is
greater than 100 mm a cut-out has to
be made in the plinth facing.
This also applies to a building-under
height A = 870 mm and plinth facing
height b greater than 150 mm.
Building-under
height A [mm]
820
870
Dimension H
[mm]
100
150