Miele CS 1028 Betriebs- und Installationsanleitung - Seite 22

Blättern Sie online oder laden Sie pdf Betriebs- und Installationsanleitung für Kochfeld Miele CS 1028 herunter. Miele CS 1028 44 Seiten. Combiset
Auch für Miele CS 1028: Betriebs- und Installationsanleitung (44 seiten), Betriebs- und Installationsanleitung (44 seiten), Konvertierungsanweisungen (40 seiten), Betriebs- und Installationsanleitung (44 seiten)

Miele CS 1028 Betriebs- und Installationsanleitung

IMPORTANT SAFETY INSTRUCTIONS

Installation
The minimum distances given in
these Installation instructions are to
combustible surfaces, and must be
observed to ensure safe operation.
Failure to do so increases the risk of
fire.
The cabinetry and venting hood
should be installed first to prevent
damage to the combiset.
~
Gas appliances should only be
installed in a well ventilated area.
~
The countertop must be bonded
with heat resistant (212°F/100°C)
adhesive to prevent distortion or
dissolving.
~
This appliance has not been
designed for maritime use or for use in
mobile installations such as recreational
vehicles or aircraft. However, under
certain conditions it may be possible for
installation in these applications. Please
contact the Miele Technical Service
Department with specific requirements.
~
The combiset must not be installed
over a dishwasher, washer, dryer,
refrigerator or freezer. Heat radiated by
the combiset may damage the
appliances.
22
~
Deep fat fryers must not be installed
directly next to gas combisets. Gas
flames can ignite splattering oil. A
distance of at least 11 5/16"" (288 mm)
should be maintained between these
two appliances.
~
Install the appliance so that the
power cord or gas piping does not
come into contact with any portion of
the combiset which may become hot
during use.
This appliance must be installed
with its own shut off valve and the
included gas pressure regulator.
Both the valve and the regulator
must be easily accessible to the
consumer after the appliance is
installed.
This appliance must be
disconnected from the gas supply
during any pressure testing of the
system performed in excess of ½ psi
(3.5 kPa). This appliance must be
isolated at test pressures equal to or
less than ½ psi (3.5 kPa).
Any pipe connections must be made
using a thread sealant approved for
gas connections. Failure to correctly
install these items could lead to a
gas leak and subsequent explosion.
Keep this instruction book in a safe
place for reference and pass it on to
any future user.