Dialight D1RW-G13-006 Handbuch für Installation und Wartung - Seite 8

Blättern Sie online oder laden Sie pdf Handbuch für Installation und Wartung für Flutlicht Dialight D1RW-G13-006 herunter. Dialight D1RW-G13-006 14 Seiten. Dual white strobe & red beacon

_____________________________________________________________________
The microcontroller board has a switch block allowing a number of options to be
set up as follows:
ON
1
White at night
2
WRED pattern for red
3
Relays pulse while OK
Relays open on fault
4
Note:
1: For both the Red Beacon and White Strobe a fault is indicated after 20
consecutive faulty flashes.
2: When the fault relays are in pulse mode and their respective light is OK, they
pulse at 0.5 seconds off and 0.5 seconds on.
Power Supply to Light Engine Cable
The connection between the power supply and light engine is made by means of
a shielded multi-way connection cable.
_____________________________________________________________________________
Dialight Corporation 1501 Route 34 South
Tel: 732.919.3119 Fax:732.751.5778 Web: www.dialight.com

Switch Settings

1 2 3 4
ON
Sheet 8 of 14
Document No.
9100-127-1109-99 Rev A
Release Date: Sept 11, 2007
OFF
Red at night
50% duty cycle for red
Relays static
Relays close on fault
Farmingdale NJ 07727