Use of the multiple circuits (where supplied)
Depending on the model, your appliance can have a DUAL or a TRIPLE heating element. When a multiple plate is
activated, the internal circuits are turned on. If you also want to turn on the outermost circuit, you need only
select the extended zone key. By means of the multiple-circuit key, the outermost circuits of the cooking zone
can be de-activated at any time. An active external circuit is shown by a special additional LED. A new activation
of the multiple-circuit key activates the external circuits again and the assigned LED s come back on.
If the element to be controlled is a triple-circuit radiant hotplate, the following applies:
Pressing the multiple-circuit button for the first time switches off the outermost circuit and the
indicator light at the top of the display.
Pressing the multiple-circuit button a second time switches off the median circuit and the
indicator light at the bottom of the display.
Pressing this button a third time, switches on the median circuit again. Further pressing adds
the third circuit and its related indicator light.
Timer Function
The hob have an autonomous timer 1-99 min.; the sound signal when time has expired
This is available only when you are not using the hob.
Autonomous timer
If the touch control is off, the autonomous timer can be used by activating the timer key. The display will
show "00". If you activate the on key, the touch control goes back to standby status and the timer is shut off.
Modifications of the value (0-99 min.), can be carried out in increments of one minute with
any of the PLUS buttons from 0 to 99 and with the MINUS button from 99 to 0.
Continuous activation of PLUS or MINUS provide dynamic increase of the speed of
variation up to a maximum value, with no sound signals.
If the PLUS (or MINUS) key is released, the speed of increase (or decrease) goes back to its original value.
The timer can be set both with continuous activation of the PLUS and MINUS keys and with
continuous activation in subsequent touches (with sound signal). After the timer has been set,
the countdown starts. When the time has expired, there will be a sound signal and the display will flash.
The sound signal stops when:
Any keys is activated.
The display stops flashing and goes off (after few minutes)
Turn off/modify timer
The timer can be modified or turned off at any time by using the PLUS and MINUS keys
(with sound signal). The timer shuts off setting the time to 0 with the MINUS key or using
the PLUS or MONO keys at the same time, which will set the timer directly to 0 without shutting it off.
If the touch control is turned on ( using the power supply key), the autonomous timer goes off automatically.
Programming timer for cooking zones
When you turn on the touch control, you can programme an independent timer for each cooking zone.
By selecting the cooking zone with the zone selection key, and then setting the power level
and finally by activating the timer key, you can set the countdown for cooking zone shutdown.
When the timer is selected, the relative display flashes, and the LED around the display come on.
If a cooking zone is selected, the LED of the timer go off and the display no longer flashes.
When the selection is modified from one zone to another, the timer display shows the timer value
associated with that zone. The timers programmed for each cooking zone.
Timers programmed for each cooking zone remain active nonetheless.
In other ways the timer behaves in the same manner as the autonomous timer.
To increase the value, the PLUS key for the corresponding cooking zone must be used.
Expiration of time is notified by an acoustic signal and by 00 on the display; the LED of the cooking zone
assigned to the timer flashes. The cooking zone is shut off, and an H is shown if the zone is hot.
Otherwise the zone display shows a dash.
Thermal protection of the control panel
When the control panel detects an ambient temperature greater than 95°C (+- 5%) it shuts off the elements.
A heating element that is shut off by the thermal protection can be only when the temperature drops below 95°C.