Dialogic DM/V480A-2T1-PCI Schnellinstallationskarte - Seite 2
Blättern Sie online oder laden Sie pdf Schnellinstallationskarte für Computer Hardware Dialogic DM/V480A-2T1-PCI herunter. Dialogic DM/V480A-2T1-PCI 2 Seiten. Media board
the board.
5. Using the slot's board guides, insert the board's edge
connector into the bus slot. Press firmly until the
board is securely seated in the slot.
Installing a PCI Board
Remove
Cover
Plate
Computer
Chassis
32-Bit
PCI Slot
6. Replace and tighten the slot's retaining screw to
secure the board firmly in the chassis (if applicable).
7. Connect external digital telephone cables to the
RJ-48C jacks on the board bracket. The topmost
RJ-48C jack is for trunk 1 and the second RJ-48C
jack is for trunk 2.
Pinouts for the RJ–48C
Network Interface
Jacks on Bracket
Cable Connector
1
2
3
4
5
6
7
8
1
RCV_RING
Pin 1
2
RCV_TIP
3
CHASSIS GROUND
4
XMIT_RING
5
XMIT_TIP
6
CHASSIS GROUND
7
CHASSIS GROUND
8
CHASSIS GROUND
8. Repeat steps 3-7 for each additional board you are
installing.
9. Use the CT Bus cable to connect the board(s) you
are installing to other boards in the system. To
preserve the electrical integrity of the CT Bus, use a
CT Bus cable with the appropriate number of
connectors ("drops"). It is recommended that no more
than two connectors at either end of the cable be left
unused.
Note:
10. Your system may include both CT Bus and SCbus
boards. To connect both board types, you must
install a CT Bus/SCbus Adapter on one of the CT
Bus boards in a system. See the CT Bus/SCbus
Adapter Quick Install Card for installation details
about the Adapter and the bus cables.
11. Install CT Bus Termination Jumpers only on boards
located at each end of the CT Bus cable. See the
"Physical Description" section for jumper details.
Installing the CT Bus Cable
PCI
Board
12. Replace the computer's cover when finished and
reconnect the power cords.
16-Bit
ISA Slot
13. Turn the computer's power ON.
CAUTION: If your BIOS is set to use Plug and Play
technology and there are ISA boards in your system, an
IRQ conflict can be created if a PCI board is assigned
the same IRQ as an ISA board. This could cause the
machine to stop responding. You can prevent this by
entering the BIOS and reserving the appropriate IRQs
(those used by your ISA boards) for ISA use only.
After Installing the Hardware
After installing the hardware, run the Dialogic
Configuration Manager (DCM) as described in the
installation instructions included with the Dialogic
System Software to configure your system.
For technical specifications and product information go
to: http://www.dialogic.com/products.htm.
Warranty and Return Information
For specific warranty information for this board, refer to
the Warranty section of the Products page, located at
this URL: http://www.dialogic.com/warranties/.
Dialogic provides technical support for its products
through a network of value added distributors who are
trained to answer technical questions on installing and
configuring Dialogic
to contact your support channel, please call Dialogic
in the United States at 973-967-6600 (9am-5pm EST)
and we will assist in obtaining the appropriate support
channel. Outside the United States please refer to
http://www.dialogic.com/support/contact
local contact information. Dialogic also provides direct
support via Dialogic
CT Bus
Colored
Cable
Stripe
(Pin 1)
Note:
Your CT Bus cable may
have a different number
of connectors (drops).
®
Warranty Period
Contacting Technical Support
®
products. If you are unsure how
to obtain
®
Pro™ Services agreements. For
more details of direct support from Dialogic please refer
to: http://www.dialogic.com/support/DialogicPro.
Returning a Product
To return a board for warranty repair or any other
returns, please refer to the following:
http://www.dialogic.com/support/hwfaults .
Sales Assistance
If you have a sales question, please contact your
local Sales Representative or the Regional Sales Office
for your area. Address, telephone and fax numbers, are
available at the Dialogic website located at:
http://www.dialogic.com/contact.htm
To purchase Dialogic
following website to locate the appropriate supplier:
http://www.dialogic.com/purchase.htm
All contents of this document are furnished for informational use only and are subject
to change without notice and do not represent a commitment on the part of Dialogic
Corporation or its subsidiaries ("Dialogic"). Reasonable effort is made to ensure the
accuracy of the information contained in the document. However, Dialogic does not
warrant the accuracy of this information and cannot accept responsibility for errors,
inaccuracies or omissions that may be contained in this document.
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH
®
DIALOGIC
PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL
OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED
BY THIS DOCUMENT. EXCEPT AS PROVIDED IN A SIGNED AGREEMENT
BETWEEN YOU AND DIALOGIC, DIALOGIC ASSUMES NO LIABILITY
WHATSOEVER, AND DIALOGIC DISCLAIMS ANY EXPRESS OR IMPLIED
®
WARRANTY, RELATING TO SALE AND/OR USE OF DIALOGIC PRODUCTS
INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A
PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY
INTELLECTUAL PROPERTY RIGHT OF A THIRD PARTY.
Dialogic products are not intended for use in medical, life saving, life sustaining,
critical control or safety systems, or in nuclear facility applications.
It is possible that the use or implementation of any one of the concepts, applications, or
ideas described in this document, in marketing collateral produced by or on web pages
maintained by Dialogic may infringe one or more patents or other intellectual property
rights owned by third parties. Dialogic does not provide any intellectual property
licenses with the sale of Dialogic products other than a license to use such product in
accordance with intellectual property owned or validly licensed by Dialogic and no
such licenses are provided except pursuant to a signed agreement with Dialogic. More
detailed information about such intellectual property is available from Dialogic's legal
department at 9800 Cavendish Blvd., 5
Dialogic encourages all users of its products to procure all necessary intellectual
property licenses required to implement any concepts or applications and does not
condone or encourage any intellectual property infringement and disclaims any
responsibility related thereto. These intellectual property licenses may differ from
country to country and it is the responsibility of those who develop the concepts or
applications to be aware of and comply with different national license
requirements.
Dialogic, Diva, Eicon, Eicon Networks, Eiconcard and SIPcontrol, among others, are
either registered trademarks or trademarks of Dialogic. Dialogic's trademarks may be
used publicly only with permission from Dialogic. Such permission may only be
granted by Dialogic's legal department at 9800 Cavendish Blvd., 5th Floor, Montreal,
Quebec, Canada H4M 2V9. Any authorized use of Dialogic's trademarks will be
subject to full respect of the trademark guidelines published by Dialogic from time to
time and any use of Dialogic's trademarks requires proper acknowledgement. The
names of actual companies and products mentioned herein are the trademarks of their
respective owners.
.
®
products, please refer to the
.
th
Floor, Montreal, Quebec, Canada H4M 2V9.