Allpro 288681 Anweisungen - Seite 4

Blättern Sie online oder laden Sie pdf Anweisungen für Farbspritzgerät Allpro 288681 herunter. Allpro 288681 4 Seiten. Mustang 500 series spray guns

Maintenance/Repair
Cleaning/Replacing Filter
1.
Relieve pressure. Engage trigger lock.
2.
Disconnect hose.
3.
Disconnect trigger guard (4) from guard retainer (22).
4.
Unscrew handle (23) from gun.
5.
Remove filter (6) through top of handle.
6.
Clean filter using a soft brush.
7.
Insert clean filter into handle.
8.
Reattach handle to gun. Tighten securely.
9.
Reconnect trigger guard to guard retainer.
Replacing Needle
1.
Relieve pressure. Engage trigger lock.
2.
Remove tip (15) and guard (2). Disconnect hose.
3.
Disengage trigger lock.
4.
Squeeze trigger while unscrewing diffuser/seat (1a). For
Series A guns, remove needle housing and gasket.
5.
Remove locknut (9) and end cap (8).
6.
Tap out needle (1b) using a plastic hammer.
7.
Use a soft brush to clean internal passages of gun.
8.
Grease o-rings of new needle using a non-silicon grease.
9.
Guide new needle into front of gun.
10. Install end cap and locknut, loosely.
11. For needle housing (1a), apply medium strength (blue)
thread sealant to threads.
12. Squeeze trigger while installing needle housing. Torque to
26-32 ft-lb (35-43 N•m).
Adjusting Needle
1.
Relieve pressure. Engage trigger lock.
2.
Remove tip (15) and guard (2). Disconnect hose.
3.
Disengage trigger lock.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
4
ASM reserves the right to make changes at any time without notice.
Original Instructions. This manual contains English. MM 312363
ASM Company, 3500 N. 1st Avenue, Sioux Falls, SD 57104
Copyright 2007
www.asmcompany.com
Revised 10/2010
4.
Hold gun with nozzle pointing up.Turn locknut (9)
clockwise (CW) until you see and feel trigger (3) raise
slightly.
5.
Turn locknut 3/4 turn counterclockwise (CCW). When
properly adjusted, trigger will move freely.
CW
ti10472a
6.
Connect hose. Install tip and guard. Prime sprayer.
7.
Trigger gun into pail until fluid flows from gun.
8.
Release trigger. Fluid flow should stop immediately.
9.
Engage trigger lock. Try to trigger gun. No fluid should
flow.
10. If the gun fails either test, repeat steps 1-9.

Technical Data

Maximum working
3600 psi (248 bar, 25 MPa)
pressure
Fluid orifice size
0.125 in. (3.18 mm)
Weight
22 oz (630 g)
(with tip and guard)
Inlet
1/4 npsm swivel
Maximum material
120°F (49°C)
temperature
Wetted parts
Stainless steel, polyurethane, nylon,
aluminum, tungsten carbide, solvent
resistant elastomer, brass
Noise level*
Sound power
87 dBa
Sound pressure
78 dBa
*Measured at 3.1 ft (1 m) while spraying water-based paint,
specific gravity 1.36, through a 517 tip at 3000 psi (207 bar,
20.7 MPa) per ISO 3744.
3/4
CCW
ti10471a
ti10473a
312363E