ALLREDI MARCO 151E Benutzerhandbuch - Seite 10

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Schalter ALLREDI MARCO 151E herunter. ALLREDI MARCO 151E 16 Seiten. Remote control switch

ALLREDI MARCO 151E Benutzerhandbuch
W-568
Use of Marco remote
control switches with
other manufacturer's
remote control systems
could cause unintended
activation of remote
control systems
resulting in the release
of high speed abrasive
and compressed air.
Only Marco remote
control switches should
be used with Marco
remote control systems.
Failure to comply with
the above warning
could result in death or
serious injury.
W-506
OSHA requires blast
cleaning nozzles be
equipped with an
operating valve, which
shall be designed to
be held open only
by continuous hand
pressure and shall
close immediately upon
release of hand pressure
(i.e., a "deadman"
control). The valve
shall not be modified in
any manner that would
allow it to remain open
without the application
of continuous hand
pressure by the
operator. Failure
to comply with the
above warning could
result in release of
high speed abrasive
and compressed air
resulting in death or
serious injury. OSHA
29CFR 1910.244(b)
W-519
This product is
not for use in wet
environments. Always
use a Ground Fault
Interrupter Circuit (GFIC)
for all electrical power
source connections.
Use of this product
in wet environments
could create a shock or
electrocution hazard.
Failure to comply with
the above warning
could result in death or
serious injury.
9
Marco
151E Remote Control Switch
®

OPERATING INSTRUCTIONS

Description

A remote control switch gives an operator the ability to remotely activate and deactivate
the remote control system at the abrasive blasting nozzle. An electric remote control switch
reduces the cycle time required to activate and deactivate the remote control system
compared to a pneumatic remote control switch. The reduced cycle time is most noticeable
when the operator is working at distances greater than 100 feet from the abrasive blasting
pot. The Marco
151E Remote Control Switch manufactured by Allredi™ features a spring-
®
assisted safety tab and control handle, providing a dual "Fail-to-Safe" design. Typical
applications include blast rooms, blast yards, bridges, oil refineries, pipelines, railcar shops,
shipyards, and storage tanks.

Operational Requirements

The following may cause safety hazards or reduced performance:
• Improper installation and/or maintenance of components.
• Use of anything other than hand pressure to activate Remote Control Switch.
• Use of electric control line smaller than 16 gauge wire.
Operating Instructions
Before using:
• Set up abrasive blasting blast pot and remote control system. (See Operator's Manuals.)
• Inspect electric control line and connectors for cracks or abrasions.
• Inspect the remote control switch for damage. Ensure Safety Tab (1) and Handle (2)
move freely without binding. Depress the handle. If the handle and safety tab are not
returned to the UP position by the springs when released, remove remote control switch
from service or repair it before using.
During use:
• To activate the remote control switch, move Safety Tab (1) forward to the DOWN position
and move Handle (2) to the DOWN position. This will allow the boss on the handle to
make contact with the micro switch.
• To deactivate the remote control switch, release the handle. The springs will return the
handle and safety tab to the UP position.
• Monitor function of remote control switch components. Malfunctioning control handles
must be taken out of service immediately and repaired or replaced.
After use:
• When abrasive blasting is concluded, inspect components for damage. Store abrasive
blasting hose with remote control switch attached in an area clear of debris and abrasive.
2
Up Position
1