Miller 028042108 Benutzerhandbuch - Seite 15

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Schweißen System Miller 028042108 herunter. Miller 028042108 24 Seiten.

SECTION 6 − MAINTENANCE & TROUBLESHOOTING

6-1. Routine Maintenance

n = Check
* To be done by Factory Authorized Service Agent
Every
3
Months
~ Coolant Filter
Every
6
Months
lCracked Parts
Every
12
Months
ZChange Coolant

6-2. Coolant Maintenance

2
Z = Change
~ = Clean
NOTICE − Clean coolant filter. Severe condi-
tions may require more frequent cleaning (con-
tinuous use, high/low temperatures, dirty envi-
ronment, etc.). Failure to properly clean cool-
ant filter voids pump warranty.
ZChange Coolant (If Using
Water)
1
l = Replace
lReplace Unreadable Labels
!
!
1
2
3
Unscrew housing to clean filter and
housing.
Changing Coolant
3
Drain coolant by tipping unit forward.
Fill with clean water and run for 10 min-
utes. Drain and refill.
NOTICE − If replacing hoses, use
hoses compatible with ethylene glycol,
such as Buna-n, Neoprene, or Hy-
palon. Oxy-acetylene hoses are not
compatible with any product contain-
ing ethylene glycol.
!
Disconnect power
before maintaining.
Reference
Disconnect cooler plug from
welding power source recepta-
cle before maintaining.
Dispose of used coolant ac-
cording to national, state, and
local codes. Do not pour down
drain.
Cooler Side Panel
Coolant Level Indicator
Coolant Filter
956172191_7-A
OM-270223 Page 11