Miller 028042108 Benutzerhandbuch - Seite 9

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Schweißen System Miller 028042108 herunter. Miller 028042108 24 Seiten.

3-1. Serial Number And Rating Label Location

The serial number and rating information for this product is located on the back panel. Use rating label to determine input power requirements and/or
rated output. For future reference, write serial number in space provided on cover of this manual.

3-2. Specifications*

.
Do not use information in unit specifications table to determine electrical service requirements. See Sections 4-3 for information on connecting
input power.
.
This equipment will deliver rated output at an ambient air temperature up to 1045F ( 405C).
Model
Coolmate 1.3 CE
*IEC Cooling Capacity States That The Water Inlet Temperature Can Not Exceed 40° C Above Ambient Temperature At A 1l/ Min Flow Rate.
**Plug Is Customer Supplied.
Recirculating Coolant System For Water-Cooled GTAW Torches And GMAW Guns.
Use With Guns/Torches Rated Up To 280 Amperes

3-3. Coolant Specifications

Do not use conductive coolant.
Application
GTAW Or Where High Frequency Current Is Used
GMAW Or Where High Frequency Current Is Not Used
Where Coolant Contacts Aluminum Parts
*Coolants 043810 and 043809 protect to -37
NOTICE − Use of any coolant other than those listed in the table voids the warranty on any parts that come in contact with the coolant (pump, radiator,
etc.).

3-4. Environmental Specifications

A. IP Rating
B. Information On Electromagnetic Compatibility (EMC)
!
This Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low−
voltage supply system. There can be potential difficulties in ensuring electromagnetic compatibility in those locations, due to con-
ducted as well as radiated disturbances.
This equipment complies with IEC 61000-3-11 and IEC 61000-3-12.
C. Temperature Specifications
Operating Temperature Range
−10 to 40°C (14 to 104 °F)
.
The correction factor on the cooling power at an ambient temperature of 1045F (405C) is 0.625.
SECTION 3 − SPECIFICATIONS
Coolant Tank
Maximum Cooling
Capacity
Capacity
5 L
1470 Watts
(5020 BTU/hr)
1.0 L/min
(1.1 qt/min)
Coolant 050024004
Low Conductivity Coolant 043810*
Distilled Or Deionized Water Okay Above 32
Coolant 050024004
Low Conductivity Coolant 043810*
Aluminum Protecting Coolant 043809*
Distilled Or Deionized Water Okay Above 32
Aluminum Protecting Coolant 043809*
°
°
F (-38
C) and resist algae growth.
This equipment is designed for outdoor use.
Input Power
Single Phase
115 VAC
50/60 Hz
2.5 Amperes
Coolant
IP Rating
IP23
Storage/Transportation Temperature Range
20 to 25°C (68 to 77 °F)
Dimensions
Weight
Length: 620 mm
20 kg
Height: 320 mm
Width: 227 mm
°
°
F (0
C)
°
°
F (0
C)
IP23 2017−02
ce-emc 4 2014-07
Temp1_016- 08
OM-270223 Page 5