Burkert 8045 Handbuch
Blättern Sie online oder laden Sie pdf Handbuch für Transmitter Burkert 8045 herunter. Burkert 8045 6 Seiten. Electromagnetic flow transmitter

8045
Type 8045 can be combined with...
Type S020
Type S020
INSERTION
Spigot
T-fitting
The electromagnetic flow meter Type 8045
has been designed for pipes with diameters
ranging from DN 06 to DN 400 and liquids
having a conductivity > 20 µS/cm.
The transmitter has a display, a keyboard and
provides 4-20 mA, relay and pulse outputs;
The version with a stainless steel sensor has
been designed for applications with high
pressures
and high temperatures
(PN16)
.
110°C)
The version with Alloy C22 electrodes has
been designed for applications with aggressive
fluids
and especially sea water ap-
(chemicals)
plications.
1)
Under reference conditions i.e. measuring fluid=water,
ambient and water temperature=20°C (68°F), applying
the minimum inlet and outlet pipe straights, matched in-
side pipe dimensions.
* F.S.= of Full scale (10 m/s)
Electromagnetic Flow Transmitter
• Sensor in solid state technology
• Shows both flow rate and volume
• Simulation: all output signals provided without the
need for real flow
• Clean in place (CIP), FDA approved
• Version with Alloy C22 electrodes
Type 2030
Diaphragm valve
Technical data
General data
Compatibility
Materials
Housing, cover, nut
PVDF sensor version
St.St. sensor version
Front panel foil
Protection lid
Screws / Seal / Cable glands
(up to
Wetted parts materials
Sensor armature
Electrodes
Gaskets
Earth ring
(PVDF sensor version)
Electrode holder
(St.St. sensor version)
Electrical connections
Complete device data (Fitting S020 + transmitter)
Pipe diameter
Measuring range
Sensor element
Fluid temperature
PVDF sensor version
St.St. sensor version
Fluid pressure max.
PVDF sensor version
St.St. sensor version
Conductivity
Accuracy
Teach-In
Standard K-factor
Linearity
Repeatability
Type 2712
Type 8644
Globe control valve
Valve islands with
with TopControl
electronic I/O
with fittings S020
(see corresponding data sheet)
PC
(glass fibre reinforced for housing)
PPA
(glass fibre reinforced)
Polyester
PSU
Stainless steel / EPDM / PA
PVDF or Stainless steel 1.4404/316L
Stainless steel 1.4404/316L or Alloy C22
FKM
(FDA agreements)
Stainless steel 1.4404/316L or Alloy C22
PEEK
(FDA agreements)
Cable glands M20 x 1.5
(for max. 1.5 mm
DN 06 to 400
0.2 to 10 m/s
Electrodes
0 up to 80°C
(32 to 176°F) (depends on fitting)
-15 up to 110°C
(5 to 230°F) (depends on fitting)
see pressure/temperature diagram
PN10
(145.1 PSI)
PN10
(145.1 PSI) (with plastic fitting)
min. 20 μS/cm
(for measured value from 1 to 10 m/s)
≤ ±2% of Reading
1)
≤ ±4% of Reading
1)
≤ ±( 1% of Reading + 0.1% of F.S.*)
≤ 0.25% of Reading
1)
www.burkert.com
PLC
2
cross-section, shielded)
- PN16
(232.16 PSI) (with metal fitting)
1)
p. 1/6