4-10. Connecting Weld Output Cables
1
Tools Needed:
3/4 in. (19 mm)
!
Turn off power before connecting to
weld output terminals.
!
Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your ma-
chine.
.
Do not place anything between weld
4-11. Remote 14 Receptacle Information
A
J
K
I
B
C L N
H
M
D
G
F
E
*The remaining sockets are not used.
6
3
4
5
cable terminal and copper bar. Make
sure that the surfaces of the weld cable
terminal and copper bar are clean.
1
Correct Weld Cable Connection
2
Incorrect weld Cable Connection
3
Weld Output Terminal
4
Supplied Weld Output Terminal Nut
24 VOLTS AC
115 VOLTS AC
REMOTE
OUTPUT
CONTROL
A/V
Ref. 802 260
AMPERAGE
VOLTAGE
GND
2
5
Weld Cable Terminal
6
Copper Bar
Remove supplied nut from weld output ter-
minal. Slide weld cable terminal onto weld
output terminal and secure with nut so that
weld cable terminal is tight against copper
bar.
Socket*
Socket Information
A
24 volts AC. Protected by supplementary protect-
or CB2.
B
Contact closure to A completes 24 volts AC con-
tactor control circuit.
I
115 volts AC. Protected by supplementary pro-
tector CB1.
J
Contact closure to I completes 115 volts AC con-
tactor control circuit.
C
Output to remote control; +10 volts DC in MIG
mode.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from re-
mote control.
M
Mode select.
N
Remote inductance control.
F
Current feedback; +1 volt DC per 100 amperes.
H
Voltage feedback; +1 volt DC per 10 arc volts.
G
Circuit common for 24 and 115 volts AC circuits.
K
Chassis common.
803 778-B