Miller S-74 MPa Plus Benutzerhandbuch - Seite 19
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Zubehör für das Schweißen Miller S-74 MPa Plus herunter. Miller S-74 MPa Plus 48 Seiten.
4-1.
Serial Number And Rating Label Location
The serial number and rating information for this product is located on the rear panel. Use rating label to determine input power requirements
and/or rated output. For future reference, write serial number in space provided on back cover of this manual.
4-2.
Software Licensing Agreement
The End User License Agreement and any third-party notices and terms and conditions pertaining to third-party software can be found at
https://www.millerwelds.com/eula
4-3.
Information About Default Weld Parameters And Settings
NOTICE – Each welding application is unique. Although certain Miller Electric products are designed to determine and default to certain typical
welding parameters and settings based upon specific and relatively limited application variables input by the end user, such default settings are
for reference purposes only; and final weld results can be affected by other variables and application-specific circumstances. The appropriate-
ness of all parameters and settings should be evaluated and modified by the end user as necessary based upon application-specific require-
ments. The end user is solely responsible for selection and coordination of appropriate equipment, adoption or adjustment of default weld
parameters and settings, and ultimate quality and durability of all resultant welds. Miller Electric expressly disclaims any and all implied warran-
ties including any implied warranty of fitness for a particular purpose.
4-4.
Unit Specifications
Welding Power
Type of Input Power
Source Type
Constant Voltage
24 Volts AC Single-
(CV)DC With 14-Pin
Phase 10 Amperes
And Contactor
50/60 Hertz
* See Section 5-7 for detailed information on wire type, wire size, and wire feed speed.
4-5.
Environmental Specifications
A. IP Rating
This equipment is designed for indoor use and is not intended to be used or stored outside.
B. Temperature Specifications
Operating Temperature Range
14 to 104°F (-10 to 40°C)
SECTION 4 – SPECIFICATIONS
and are incorporated by reference herein.
Wire Feed Speed*
Standard: 50 To 780
ipm (1.3 To 19.8
mpm)
Control
Wire Diameter
Overall Dimensions
Range*
0.035 To 5/64 in. (0.9
Width: 12-1/2 in. (318
To 2 mm)
IP Rating
IP2X
Storage/Transportation Temperature Range
-4 to 131°F (-20 to 55°C)
Weight
Length: 27 in. (686
mm)
20 lb (9 kg)
mm)
Height: 14 in. (356
mm)
OM-289404 Page 13