SECTION 6 – MAINTENANCE & TROUBLESHOOTING

6-1. Routine Maintenance

3 Months
Replace
unreadable
labels.
Replace
cracked
parts.
6 Months
Blow out or vacuum
inside. During heavy
service, clean
monthly.

6-2. Replacing Fuses

Push And Turn
OM-189 530 Page 24
Clean and
tighten
weld
terminals.
Check
14-pin
cord.
OR
Pull Out And
Replace Fuse
YDisconnect power before maintaining.
Repair or
replace
cracked
weld
cable.
Check gas
hose and
fittings.
Clean
drive
rolls.
1
2
3
Push And Turn
Check
gun
cable.
YTurn
Off
welding
power
source and weld control.
See Parts List for size and rating of
fuses.
1
Fuse F1
Fuse F1 protects the wirefeed motor
and motor drive board from over-
load. If Fuse F1 opens, the wirefeed
motor stops. Check for jammed wire,
binding drive gear, or misaligned
drive rolls. Correct problem and re-
place F1.
2
Fuse F2
Fuse F2 protects the VL-M4 internal
control circuits and the 115 vac sup-
plied to pin A of 17-pin receptacle
from overload. If F2 opens, all opera-
tion stops. Correct problem and re-
place F2.
3
Fuse F3
Fuse F3 protects the volt sense cir-
cuit from overload. If F3 opens, volt-
age feedback will be lost when using
a constant current power source with
the VL-M4 in the CC mode. Correct
problem and replace F3.
Ref. 802 531