1. Rotating remove the filter case as pic l,pic 2 is showed when finished.
2. According to the direction of the arrow showed in pic 3, push the insurance
clasp,rotating remove the impeller chamber, pic 4 is showed when finished.
3. Remove the rotor combination as pic 5, then you can clean or change.
4. The installation position of the O-ring as pic 6.
lf the pump is not used for a long time,please pull out the pump,it is better to run
the pump in the clean water for a short time.And then rinse with clean water.Clean
and make sure the pump is dry,put it in a stable place. lf the temperature is below
0 degrees,the water in the pump should be disch -arged immediately.ln order to
prevent freezing damage of water pump.

Troubleshooting

Malfunction
Pump do not run
Pump noise
Pump water shortage
www.aquaristikwelt24.de
Cause
• No power supply
• Burning machine
• lmpeller stall
• Run without water
• Not connected with
the controller
• The controller is
damaged
Dirty inside or Shaft break
Ceramic shaft wear
• Damage
of
impeller
• lnlet
and
outlet
obstruction
• Filter case obstruction
• Under voltage
Solving measures
• Connect power
• Change pump
• Clean and relink to power
• Fill with water and relink to
power
• Relink the controller
• Chanae the controller
Clean pump or change rotor
and ceramic shaft
the
• Change rotor combination
• Clean and relink to power
• Adjust the voltage