Counterbalance Indicator Dial
Operating Instructions
3 Counterbalance Control
The counterbalance system was designed to neutralise the
effect of the camera weight when it is tilted. The Skyline 90
Fluid Head offers a continuous counterbalance system which
can be operated via the COUNTERBALANCE SELECTOR (fig.
6). The COUNTERBALANCE SELECTOR must be operated
when the SLIDING PLATFORM is in a horizontal position.
3.1 Hold the camera and disengage the Tilt Safety Lock (ensure
you have set the counterbalence to at least 80%) move the tilt
drag setting to 0 (zero).
3.2 Gently tilt the camera from a horizontal position forward then
backward and observe its response. If the Camera 'springs
back' to the horizontal position then a lower Counterbalance
setting is required, drop the setting by 10 units on the
Counterbalance position and recheck, select lower setting
again if necessary.
Inversely if the camera is dropping further forward when tilted
then not enough counterbalance is selected, increase by 10
units (or until camera no longer drops at set tilt position).
Correct counterbalance setting has been achieved when
minimum effort is required to move the camera over the
entire tilt range.
Fig. 6
8