4-1. Specifications
Input
Power
Rated Output
3-Phase
350 A at 34
VDC, 60%
Duty Cycle
*See Section 4-4 for Duty Cycle Rating.
4-2. Features And Benefits
Auto-Linet Power Management Technology is circuitry that automatically adapts the power source to the primary
voltage being applied (see Section 5-9).
LVCt Line Voltage Compensation is circuitry that keeps the power source output constant regardless of input pow-
er fluctuation.
Wind Tunnel Technologyt circulates air over components that require cooling, not over electronic circuitry, which
reduces contaminants and improves reliability in harsh welding environments.
Fan-On-Demandt cooling system operates only when needed, reducing noise, energy use and the amount of con-
taminants pulled through the machine.
Thermal Overload Protection automatically shuts down the unit, only when necessary to prevent damage to internal
components if the duty cycle is exceeded or air flow and cooling are restricted (see Section 4-4).
Auto Remote Sense enables the unit to automatically sense the connection of a remote control.
Synergic Pulsed MIG Operation allows single knob control of the arc. As wirefeed speed is increased or decreased,
the pulse parameters increase or decrease matching the power output to the wire speed (see Section 6-2).
4-3. Arc Controls
Inductance influences the arc stiffness, bead width and appearance, and puddle fluidity in MIG Welding Mode (see
Section 7-2).
SharpArct optimizes the size and shape of the arc cone, bead width and appearance, and puddle fluidity in Pulsed
MIG Welding Mode (see Section 7-4).
OM-245 171 Page 14
SECTION 4 − INTRODUCTION
Voltage Range in
Max. Open-Circuit
CV Mode
Voltage
10−38 V
75 VDC
RMS Amps Input at Rated Load
Output, 50/60 Hz 3-Phase at
NEMA Load Voltages and Class I
Rating
IP Rating
230 V
400 V
23
36.1
20.6
460 V
KVA
KW
17.8
14.2
13.6