14
E Z C L E A N | C O M P R E S S E D A I R S U P P LY U N I T | O I/ E ZC L E A N - E N R E V. A
7

Specifications

Compressed air unit
Dimensions*
Height: 395 mm (15.5 in)
Width: 330 mm (13.0 in)
Depth: 205 mm (8.1 in)
Enclosure material
Polypropylene
Pump unit
Power
90 W
Pressure relief valve
Set to vent to atmosphere if pressure exceeds
1.38 bar(g)/(20 psi(g))
Pneumatic pressure/flow rate
Maximum pressure:
• outlet closed: 3.5 bar(g)/(50.7 psi(g))
• outlet open: 2.0 bar(g)/(30 psi(g))
Typical operating pressure and flow rate 1.38 bar(g)/
(20 psi(g))/@ 14.16 L/min (0.5 scfm), set to perform every
4 hours
TORR
0
200
400
600 760
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
30
20
10
INS HG
Figure 9 Pump unit – pneumatic pressure/flow rate
*
Excluding mounting brackets, see "Installation" on page 6 for bracket dimensions
BAR
0.5
1.0
1.5
2.0
25
20
15
10
5
0
10
20
30
PSIG
Environmental ratings
Storage temperature
-20 to 50 °C (-4 to 122 °F)
Operating temperature
-20 to 50 °C (-4 to 122 °F)
Power requirements
Mains power supply
230 or 115 V AC, 90 W
Internal fuse
2 A, antisurge
Cable entries
Mains voltage supply cable
M20 cable gland
Relay cable
M20 cable gland
Pneumatic entry
Bulkhead push-fit connector for 6 mm nylon tubing
Compliance
CE
UKCA