6. Clean water faucet installation

Drill the hole in the sink (table top) 12 mm diameter;
‰
Put on the thread tail of the faucet (11) rubber gasket (2), decorative stand (3), rubber gasket (4) and
‰
insert the faucet into the hole in the sink;
Underneath the sink, put plastic (5) and metal (6) lock washers on the thread bushing and screw on the
‰
fastening nut (7);
Put on the captive-nut (9) on the plastic pipe (10) with pressed metal bushing (8) (fig. 8) and screw on the
‰
nut onto the tail end of the faucet.
Figure 8. Tube connecting to the clean water faucet procedure