User's Manual & Warranty

troubleShooting

probleM
no or limited
water flow
leaking from taps
leaking from top /
bottom of unit
not cooling
noise from fan
no water flowing
from taps /
freezing
bad taste from
cooler
poSSible CauSe
Tank is not placed properly
on unit Or, tank contains
water prior to placement
on base, or, base unit collar
contains water.
Silicone in tap is not sealing
properly
.
- or tap cracked
1.Rubber plug not inserted.
2.Drain plug at bottom
back of unit.
1.Make sure it is plugged in.
2.Is it switched on at back
of unit. .Is the fan running.
.Is green light working.
Due to transport or knock
to side panel, the fan may
have moved to a different
position - this will cause a
noise.
1.Air block. 2.Freezing
(cooling system over
cooling). .water level in
bottle is too low. .Filter is
too old.
1.New, new silicone, new
tap. 2.Build up of bacteria.
Solution
Press filter tank firmly onto the unit to allow
opening of anti-spill valve. Ensure that between filter
tank and unit no gap remains. Also ensure that the
filter tank is empty as well as the base unit collar
before placing filter tank on base unit. Place filter
tank on unit prior to filling with water.
Unscrew toggle portion of tap (top), fasten again and
taggle the lever back and forth, If not rectified tap requires
replacement.
Remove filter bottle & push plug in, if you need
replacement plug contact customer service for advice.
Please ensure the drain cap at bottom back of cooler is
tight - if missing it must be replaced.
Once power switch is checked; then check fan is running
and green light is working - If yes, the cooler is to be
returned.
Unfortunately cooler is to be returned for repair/
replacement.
Check to make sure the filter doesn't need replacing.
Replace filter, remove filter bottle and wash thououghly.
place a tablespoon of bi-carb soda mixed with warm water
approx. 1 litre, pour in cooler until the tap reservoir is full,
leave overnight and then flush 68 - 102 oz of filtered water
through the unit until the b-carb solution has been flushed
clean.
9