Installation Instructions

When installing these appliances, all local regulations, including those referring to national and European
Standards need to be complied with.
This manual covers the appliances: Burley Models: 9103, 9104, 9105, 9108 and 9112
The nominal space heating output is:
'Springdale' 9103: 3Kw
'Debdale' 9104: 4Kw
'Hollywell'
9105:
5Kw
'Brampton'
9108:
8Kw
'Wakerley' 9112: 12Kw
Any of the above appliances must be installed by an installer registered with a competency scheme (ie
HETAS/ELECSA England & Wales), conforming to Building Regulations Part J and the installation must be
registered with the local council building control department.
Failure to comply with the above renders all guarantees and liabilities of the manufacturer
null and void.
By carefully following the instructions below we are certain that you will enjoy many years of warmth and
enjoyment from your new Burley Fireball Stove.
The manufacturer will not guarantee or accept liability for any problem that arises unless a local authority
building control certificate has been completed and a valid receipt or proof of purchase is presented from
the approved supplier.
The appliances should not be fitted closer to combustible materials, e.g. wooden fire surround or stud wall,
than is shown in the table on page 6.
When fitted against a wall made of combustible material e.g. a wooden stud wall with plasterboard, unless
a 75mm thick non-combustible material is used as a barrier, extra non-combustible material should be fitted
behind the stove if the distance from the wall is less than shown. When fitted inside a masonry or similar
non-flammable material recess, e.g., fireplace opening, there is no minimum distance; although we would
advise a minimum of 50mm from any surface to allow for convection.

Approvals

All our wood stoves are approved to EN13240:2001 and EN13240 A2:2004.
DEFRA Approval
The 9103, 9104, 9105 and 9108 models have been approved by DEFRA for use in smokeless
areas. They have been designed and tested with a special air plate (see below).
The plate restricts the air at high rate, but allows air into the stove when shut down to reduce the
potential for producing smoke.
Due to its huge heat ouput, the 9112 has not been submitted for DEFRA approval.
Web site: http://smokecontrol.defra.gov.uk/appliances.php?country=e