Diamond PL 300 Betriebs- und Wartungshandbuch - Seite 7
Blättern Sie online oder laden Sie pdf Betriebs- und Wartungshandbuch für Kommerzielle Lebensmittelausrüstung Diamond PL 300 herunter. Diamond PL 300 16 Seiten. Professional slicer ce
the position of two of the three phase
wires (black, gray or brown) in the plug.
2.3.5 - Electrical connection modification
Unless otherwise specified, the slicers are equipped with 400 V. three-phase
connection. To modify the connection carefully follow these instructions:
remove the plug from the electric network;
-
turn the slicer on the side opposite the trolley;
-
take off the yellow cover from the electrical box;
-
remove the motor cables from the electronic card;
-
connect wires from the motor that have the same colour (white-white, blue-
-
blue, etc.);
reconnect them to the electronic card;
-
check the positioning of the feed selection plugs on the electronic card (Fig. n°
-
21);
close the box, reposition the slicer and proceed as in par. 2.3.3.
-
2.4 - ELECTRICAL DIAGRAM - 230V. SINGLE-PHASE - 230V.
THREE-PHASE - 400V. THREE-PHASE, 'SIDNEY' PUSH-BUTTON
Fig. n°20
Fig. n°21
10
2.4.1 - Single-phase 230 V. tension selection
OUTPUT DIAGRAM
2.4.2 - Three-phase 230 V. tension selection
2.4.3 - Three-phase 400 V. tension selection
11