Problem
The unit display does not turn on
The unit display does not cool enough
The top side isn't cold
Mist appears on the doors
Doors don't close properly
None of the led light are turning on
Part or one strip of led lights is not turning on
The maintenance and repair must be performed by qualified personnel only. Before any operation unplug the unit.
A. OPENING THE TECHNICAL BASIN
A1. Extract the plastic clip from
the right hand side on the
alluminium rods
B. EXTRACTION / REPLACEMENT DOORS
B1. Unscrew the upper hinge on the
top of the unit
PROBLEM SOLUTION GUIDE
Potential cause
The unit is disconnected
General switch deactivated
Fautly thermoregulator
The Ambient temperature is too high
The doors get frequently opened
The doors are not completely well closed
The lateral grids are obstructed
The temperature controller isn't set in correctly
The Energy Saving is active
The condesator fan is broken
Lack of gas in the cooling system
Cooling system broken
The inner fans are switched off
The inner fans are broken
The ambient humidity is very high
The inside temperature is too low
The unit display isn't on an even surface
The switch on the temperature controller is off
A cable has disconnected from the wiring
The power supply is broken
The RGB controller is broken
The led strip is broken
A2. Move towards left 3 rows of rods
or unscrew them ( Depends on
the model)
B2. Pull the door outward
Check the connection to wall socket
Check the power on the socket
Turn on main switch under the unit display
Replace the thermoregulator (G)
Pay attention closing the shutters to the frame
Leave 10cm gap on the right and left side of the external units of the assembly
Check the set point of the temperature controller
Deactivate Energy Saving from the temperature controller
Replace condesator fan (L)
Check level of gas and type
Replace completely the wiring or a part of it (M)
Activate inner fans switch on the temperature controller
Replace inner fans (I)
Excise cause or switch on the anti-fog device (optional)
Turn up the unit display temperature
Level the unit display on a straight surface adjusting the pins
Activate the light switch
Check the wiring
Replace the power supply
Replace the RGB receptor (F)
Repace the broken led strip (E)
A3. Remove the alluminium panel
B3. Lift the door to realease from
the lower hinge
ENGLISH
Solution
Excise cause
Excise cause
A4. Remove the lids underneath
unscrewing the screws