BEFORE INSTALLING
2
Water Quality Parameters
Aquasana recommends the installation of a Pre-Filter of at least 5-microns prior
to the Aquasana UV Filter system. For the UV Filter to effectively kill bacteria
and viruses, the UV light must be able to pass through the water it is treating.
Treated water should be tested for at the least the parameters listed below:
Hardness: <7 gpg (120 mg/L) (If hardness level is 7pgp or slightly below,
the Quartz Sleeve must be cleaned periodically for efficient UV penetration;
if above the water must be softened)
Iron (Fe): < 0.3 ppm (0.3 mg/L)
Manganese: <0.05 ppm (0.05 mg/L)
Turbidity: <1 NTU
Tannins (organics): <0.1 ppm (0.1 mg/L)
UVT (transmittance): >85%
If your water exceeds the listed parameters above, Aquasana strongly
recommends that pre-treatment equipment be installed (equipment required
will depend on parameters being treated). Contact the Aquasana Sales
Department to have your water tested: 866-662-6885.
Prior to Installation
• For all installations: Anticipate the need for additional parts and
pieces including but not limited to pex tubing, clamps, and mounting
screws to install unit properly (available at local home improvement
stores or through your plumbing contractor).
• We recommend that a licensed plumber or certified technician install
the UV Filter. Installation of the UV Filter must comply with existing state
and local plumbing codes. Some local codes may require the use of a
licensed plumber or certified installer when disrupting a potable water
line. Aquasana and its manufacturer are not liable for consequential or
incidental damages due to improper installation.
• It is recommended your UV Filter be installed indoors and out of direct
sunlight. If this is not possible and the system is outdoors or in a sunny
area, the unit must be protected from both direct sunlight and freezing
temperatures.