Aquasana OptimH2O AQ-RO-3 Benutzerhandbuch - Seite 12
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Water Filtration Systems Aquasana OptimH2O AQ-RO-3 herunter. Aquasana OptimH2O AQ-RO-3 14 Seiten. Whole house water filter
Auch für Aquasana OptimH2O AQ-RO-3: Benutzerhandbuch (11 seiten), Benutzerhandbuch (10 seiten), Benutzerhandbuch (16 seiten)
3-STAGE
RO SYSTEM
-
MODEL
AQ-RO-3
Metric
U.S.
Membrane Production1
35
gpd
132
Ipd
Membrane
TDS
Reduction1
95% minimum
95% minimum
System
Production2
13-32
gpd
50.4
Ipd
TDS
Reduction2
96.3%+
average
96.3%+
average
Maximum
TDS
1000
ppm
1000
ppm
Maximum
water
hardness
@
6.gpH
2.64
gpL
logpg
Maximum Chlorine in
water
3.0 ppm
3.0 ppm
Supply
water
pH
limits
4-10
4-10
Drain (reject water) Flow
3-5 x product flow
3-5 x product flow
Empty Storage Tank
Precharge
35-48
k
Pa air
5-7 psi air
Storage
Tank Capacity2
3.2
gallons
i2.ii
liters
Supply
water
pressure limits
275-689
kPa
40-100
psi
Supply
water
temperature
limit
40-100°
F
5-37°
C
Efficiency3
17.91%
17.91%
Recovery4
29.43%
29.43%
Specifications
-
Qualified
System
Performance
Because
the performance of
a Reverse Osmosis
Membrane
is
highly dependent
upon pressure,
temperature
and
TDS,
the following should be used for comparison purposes only.
1
Industry standards
measure RO
Membranes performance with
no
back pressure
on
the
product
water, at 60
psig (4i4l<Pa) and
77°F
(25°C). Further conditions
on
the above
are 250
ppm
TDS
and
a
30.6%
recovery
rate.
Production
rate
and
TDS
reduction figures
are
for
a new
Membrane that has been rinsed for
24
hours. The production
rate
of
a new
Membrane
can
decrease by
10%
per year
or more,
depending
upon the
scaling and fouling tendencies of the
Feed
Water.
2
Measured
at
50
psi, 77°+2°F, and 717 mg/I
TDS
per
NSF/ANSI
Standard
58.
3
Efficiency rating
means
the
percentage
of the influent
water to
the
system that is
available
to
the
user as reverse osmosis
treated
water.
Under operating conditions that
approximate
typical daily usage.
4
Recovery rating
means
the
percentage
of the influent
water to
the membrane portion of
the system that is available
to
the user as reverse osmosis treated
water
when the
system
is
operated
without
a storage
tank
or
when the storage tank is
bypassed.
/j\
Do
not use
with
water
that is microbiologically unsafe
or
of unknown
water
quality
without adequate disinfection before
or
after the
system. Systems
certified for
cyst
reduction
may
be used
on
disinfected
waters
that
may contain filterable cysts.
/5\
Filter is only
to
be used with cold
water.
Systems certified for cyst reduction may be
used
on
disinfected
water
that
may contain filterable cysts.