the documents, make a precise report on the damage to the machine. Do not
overturn the package!! When transporting it make sure that it is firmly held
by the four corners (keeping it parallel to the floor).

CHAP. 2 - INSTALLATION

WARNING!
All operations must be carried out by
specialized personnel (Fig. n°9).
2.1 - UNPACKING
Remove the straps from the package
(Fig. n°10) and lift the cardboard (h).
The package should be:
a)the machine on the pallet (Fig. n°11
detail a);
b)blade extractor (Fig. n°11 detail e);
c)4 feet (Fig. n°11 detail f);
d)Case, if present (Fig. n°11 detail b).
Check inside the suitcase if it present,
find the following components:
(Fig. n°11):
1.Instruction manual (detail d) ;
2.CE compliance certificate (detail c);
3.Audio-visual cd;
4.Liquid detergent with sprayer;
5.Oil tube;
6.Sharpening and burring grinders;
7.Socket wrench to remove grinders;
8.Grinders brush;
9.Large and small screwdrivers.
10.
Pliers.
Fig. n°9
h
Fig. n°10
b
a
c
d
Fig. n°11
6
2.2 - POSITIONING
Position the pallet, with the slicer, on a
flat surface and take off (a) the cap
from the slicer (Fig. n°12).
At this point turn the machine on its
side (Fig. n°13) and unscrew, with the
proper wrench provided, the 4 nuts
which fasten the slicer. Remove the 4
washers and unscrew the 4 fastening
tie rods on the wooden pallet. Take off
the pallet and fasten the 4 feet provi-
ded. Finally, put the cap in its place.
Position the slicer in the predestined
place.
The dimensions indicated in Tab. 1-2-3
(according to the model) must be kept
in mind for the plane where the slicer
will be installed, therefore it must be
wide enough, well-levelled, dry,
smooth, robust, stable about 80 cm
high off the ground and at least 20 cm
from walls, objects, shelves, etc. (Fig.
n°14) in respect to the space
necessary for its use and safeguarding.
Furthermore the machine must be
placed in an environment with a maxi-
mum humidity of 75%, not salty and
with a temperature between +5°C and
+35°C; in any case in environments
which do not lead to deviations of the
above.
Make sure the graduated hand grip is in
posiion "0".
Check the alignment of the blade-plane
thickness gauge by running a finger
(Fig. n°16) from the blade towards the
thickness gauge plane (never in the op-
posite direction). Unscrew and screw
the feet on the operator's side until the
correct alignment is found (Fig. n°17).
a
Fig. n°12
Fig. n°13
20cm
20cm
20cm
~ 80cm
Fig. n°14
Fig. n°15
Fig. n°16
Fig. n°17