Electronic shutter settings

Shutter modes

Shutter modes and shutter speeds that can be set
Mode
Shutter speed
Standard
1/100, 1/120, 1/250,
1/500, 1/1000 and
1/2000 (sec.)
SYNCHRO
Within the 60.3 Hz to
SCAN
250.0 Hz range
SUPER V
<Notes>
≥Whatever mode is set for the electronic shutter, the faster the
shutter speed, the lower the camera's sensitivity.
≥In the automatic iris mode, the faster the shutter speed, the more
the iris opens and the shallower the depth of focus.
≥When SUPER V has been selected, the camera's sensitivity will
be halved.

Setting the shutter mode and speed

≥In the shutter speed and standard mode, the shutter speed is set
by selecting the SHUTTER switch position.
≥In the SYNCHRO SCAN mode, the shutter speed can be easily
changed by operating the JOG dial button.
1
Push the SHUTTER switch from ON to
SEL.
The current shutter setting appears in the area of the
viewfinder screen where messages notifying the user of
changes made to settings appear.
SHUTTER switch
JOG dial button
Applications
For shooting fast-moving subjects
clearly
For shooting monitor screens with
minimal striping in the horizontal
direction
For improving the vertical resolution
2
Press the SHUTTER switch to SEL again,
and repeat until the desired mode or
speed is displayed.
When all the modes and speeds are displayed, the display
changes in the following sequence.
1/100
1/120
SUPER V
mode
<Note>
The SUPER V mode is not selected as the factory setting. For this
reason, it is not displayed at the factory setting.
To select SUPER V mode, set the "SUPER V" of the sub-menu
<SW MODE> screen to ON. (See page 33)

Setting the synchro scanning mode

1
Push the SHUTTER switch from ON to SEL
and set to SYNCHRO SCAN.
The setting can be continuously selected within the 60.3 Hz to
250.0 Hz range by rotating the JOG dial button up or down.
<Note>
After the JOG dial button is rotated up or down while being pressed,
the setting will continue to change as long as the button is pressed
(even without the button being rotated).
21
Standard mode
1/250
1/500
1/1000
1/2000
SYNCHRO SCAN
mode