AquaScape Ultra 1500 Unterweisung und Wartung - Seite 5

Blättern Sie online oder laden Sie pdf Unterweisung und Wartung für Water Pump AquaScape Ultra 1500 herunter. AquaScape Ultra 1500 16 Seiten. Fountain and statuary pump
Auch für AquaScape Ultra 1500: Anleitung und Wartung (16 seiten), Handbuch für Installation und Wartung (7 seiten)

• It is recommended that the pump NOT be positioned in
the deepest area of the pond. This will protect the fish
by preventing the pond from completely draining in the
case of a leak in the plumbing or filter. If needed, bricks or
stones can be used to raise the pump off the bottom of
the pond.
• The Ultra Water Pump includes an assortment of fittings
for a wide variety of plumbing options. Select and install
the appropriate fitting(s) for your application.
• The included Multi-Hose Adapter(s) is (are) designed to
accommodate different diameters of tubing and ideal for
applications using a single plumbing line.
• The Multi-Hose Adapter can
be threaded directly into the
discharge of the pump
(Ex. 3).
• If using a diameter of pipe
that is larger than the
smallest section of the Multi-
Hose Adapter, trim off the
smaller sections to prevent
flow restriction (Ex. 4).
• The included threaded
FPT 90° elbow allows the
water flow to be directed
horizontally, perfect for
fountain basin applications
where vertical space is
limited (Ex. 5).
• To install the elbow, attach
the included MPT Coupling
to the discharge of the
pump. Then thread the
collared elbow fitting to the
MPT Coupling to attach it to
the pump.
• The collared connections
allow the pump to be quickly
and easily disconnected
from the tubing for pump
removal or maintenance.
• The convenient included 1/2" Valve (400/550/800) (Ex. 6)
or 3/4" 3-Way Valve (1100/1500/2000) (Ex. 7) provide the
ability to customize flow rates.
Ex. 6
aquascapeinc.com |
CAN (866) 766-3426 |
• The included flow control
valve can be installed directly
into the pump discharge or
installed horizontally using
the threaded FPT 90° elbow
(Ex. 8).
• Once installed, simply adjust
the valve(s) to dial in the
desired water flow.
• When using the 3-Way Valve, close off any unused valves
to maximize water flow to the valves in use.
• Attach the tubing to the
selected fitting(s) (Ex. 9)
using a twisting motion
(Ex. 10). If the tubing fits
loosely, a hose clamp (not
included) can be used to
secure the attachment.
• In some instances the tubing
may be difficult to attach to
Ex. 3
the selected fitting. If this is
the case, we recommend
heating the hose with a
hair dryer or simply dipping
the hose in very hot water
for a few seconds prior to
attachment. Lubrication
can also be used; we
recommend silicone grease
or olive oil.
Ex. 4
• Connect the other end of the pump tubing to the
decorative fountain or pond filter.
• Connect the pump to
an outlet (Ex. 11) that is
protected by a ground fault
circuit interrupter (GFCI).
Once the pump is running
and water is circulating,
check for leaks where the
Ex. 5
external connections are
made.

General Maintenance

• We recommend inspecting your pump on a regular basis
to make sure it is functioning properly. If water flow is
reduced, it may be due to
the filter screen or sponge
being clogged with debris.
• The front screen can be
removed by twisting the
locking knob counter-
clockwise and pulling the
Ex. 7
screen off (Ex. 12).
US (866) 877-6637
Ex. 8
Ex. 9
Ex. 10
Ex. 11
Ex. 12
5