AQUASTREAM ABSC02789 Handbuch für Installation, Betrieb und Wartung - Seite 9
Blättern Sie online oder laden Sie pdf Handbuch für Installation, Betrieb und Wartung für Inverter AQUASTREAM ABSC02789 herunter. AQUASTREAM ABSC02789 20 Seiten.
Residential Steambath Generator Systems
Electrical Specifications
All electrical wiring to be installed by a qualified licensed electrician in accordance with National
E lectrIcal Code and local electrical code.
Power Wiring
See " Field Power Wiring" Diagrams (Page 8)
1. Check power voltage. Use 240V/ 1ph to connect S H
2. Use minimum 90ºC /600V rated insulated copper conductors only for field wiring, sized in accordance
with National E lectrical Code and local electrical code for the Amps in Ampere Chart.
3. Connect suitably sized equipment grounding wire to ground terminal provided.
4. Install a separate circuit breaker between supply and unit. Provide a power supply disconnect
within sight of the steam generator or one that is capable of being locked in the open position.
____________________________________________________________ __
____________________________________________________________ __
Maximum Room
Model No.
Volume ft
_______________________________________________________________________________________
ABSC02787
225(6.37)
_______________________________________________________________________
ABSC02789
360 (10.19)
__________________________________________________________________________
ABSC02782
575 (16.82)
_________________________________________________________________________
Wiring Diagrams
Diagram
for ABSC02787
ABSC02789
Diagram
for ABSC02782
!
caution
TO AVOID EQUIPMENT DAMAGE DO NOT
CONNECT POWER SUPPLY DIRECTLY TO
HEATING ELEMENTS !!!
a qu as te a m
Ampere Chart
Voltage/
3
(m
2
)
KW
phase
7.5
240/1
9.0
240/1
12
240/1
POWER INPUT
L1
L2
G
BLACK
BLACK
GREEN
GROUND
WHITE
C
LIGHT
BLUE
CONTACTOR
S
WATER
FEED
SOLENOID
HEATING
VAVLE
ELEMENT
POWERINPUT
L2
L1
BLACK
BLACK
GREEN
PURPLE
FUSES
GROUND
C
CONTACTOR
S
WATER
FEED
SOLENOID
HEATING
VALVE
ELEMENT
residential steambath generator.
Wire Size
Amperes
AWG (mm
32
8 (10)
38
8 (10)
50
6 (16)
TRANSFORMER
WHITE
DARK
BLUE
PURPLE
TO PROBE
WHITE
GRAY
CONTROL BOARD
TRANSFORMER
WHITE
DARK
BLUE
PURPLE
TO PROBE
WHITE
LIGHT
BLUE
WHITE
GRAY
CONTROL BOARD
2)
L E G E N D
(
All Diagrams)
FIELD
WIRING
FACTORY
WIRING
AUTOMATIC DRAIN
(optional)
L E G E N D
(All Diagrams)
FIELD
WIRING
FACTORY
WIRING
Automatic Drain
(optional)
7