AQUASYSTEM AMH1-25SUS Betriebshandbuch - Seite 7

Blättern Sie online oder laden Sie pdf Betriebshandbuch für Water Pump AQUASYSTEM AMH1-25SUS herunter. AQUASYSTEM AMH1-25SUS 12 Seiten. Air-motor type centrifugal pump

AQUASYSTEM AMH1-25SUS Betriebshandbuch

How To Use

Before Operation starts
1. Be sure again if the pump, flange and other pipe connectors are not
loosened. Also, be sure if bolts and/or screws at each part of
motors/pumps are firmly fixed.
2. Supplying Air Pressure:0.4~0.6 MPa
3. Acceptable viscosity:Up to 2,000 cP
4. When the pump is disassembled due to inspection and/maintenance,
be sure if all parts are firmly fixed, every time when re-assembled.
5. Once again, we advise our valuable customers carefully to read our
Operation Manual (P. 1-4).
During Normal Operation
1. In case the pipes, hoses and valves etc. are connected,
be sure that they are firmly connected each other.
2. Ground wire
before
3. Air-plug should be gradually opened. Control the discharging volume
with air-valve angle.
※In case of "Under dry condition" or "Under non-use condition for
a long time", be sure, first of all, to fill the liquid (approx. 200 cc)
through the priming plug located at upper portion of pump.
4. Be sure that vibration and/or noise are stable.
Stop Operation
1. Close air-plug. (No discharging operation is allowed.)
2. The liquid can be taken out through the drain plug.
(If the liquid remains in a pump, it may generate the rust inside
of pump, which may cause mechanical troubles and/or damage
the performance.)
operating by all means.
Priming and Drain plug
6
Air Plug
Ea
Kits r