Never fail to perform this after the update
After AU-V35C1 is updated, please perform ABB with the lens cap fitted on
according to the procedure. This is for the sensor adjustment needed after
120p mode is newly equipped.
Only the first ABB adjustment after the update is definitive. It cannot be
done over again.
Please be careful because, if it is not successfully completed, the product
will not work correctly when you use it.
MENU : SYSTEM SETTINGS > SYSTEM MODE
FREQUENCY
PIXCEL
MAIN CODEC
HIGH SPEED
Reboot the camera and wait for 15 minutes or longer with the power on.
Check SENSOR TEMP and, if it is not between 38℃ and 43℃, wait for a further 15 minutes or so.
MENU: SYSTEM SETTINGS > INFORMATION > SENSOR TEMP
(Temperature readings can be updated by pushing the jog dial button two times.)
Be sure to put the lens cap or mount cap to block out the light completely.
(If you proceed to the next step without blocking the light, you cannot perform
ABB again by MENU even after it is not completed.)
MENU: SYSTEM SETTINGS > COLOR SETTING
MAIN
V-709
MENU: CAMERA SETTINGS > Enhanced > Enhanced SW > ON
MENU: CAMERA SETTINGS > BLACK > ABB
[EXECUTE]
After about a minute, "ABB ACTIVE" is displayed on the panel.
When "ABB OK" is displayed, ABB is completed.
However software cannot be updated, please contact Panasonic Service Engineering.
59.94p
4096 x 2160
AVC-Intra4K-LT
ON (60-120fps)
Page4/5
Firmware update procedure for Varicam series
between 38℃ and 43℃
January 2015