System Specifications
Figure 1. Specifications
•
C indicates cabinet Models
•
Maximum Water Temperature = 110°F (43°C)
•
Maximum Operating Pressure = 100 PSIG
(689 kPa)
•
Voltage = 110 volts standard
How Your Water Conditioner Works
The unique two tank system keeps the two media beds separate and allows for more carbon contact time improving
chlorine, chloramines, and organics removal.
The principle behind water softening is simple chemistry. A water softener contains resin beads which hold electrically
charged ions. When hard water passes through the softener, calcium and magnesium ions are attracted to the charged
resin beads. It's the resulting removal of calcium and magnesium ions that produces soft water.
This valve is controlled with simple, user-friendly electronics displayed on a large LCD screen. The main page displays the
current date and time. In addition, the main page also shows key valve information and statistics including; current
capacity setting, volume remaining, date of last regeneration, current flow rate, and peak flow rate.
NOTE:
REGEN DAYS and REMAINING DAYS are only shown in the CALENDAR CLOCK more or METER OVERRIDE mode.
MAY 8, 2009
9:05 AM
REGEN DAYS
REMAINING DAYS
7 DAYS
LAST REGEN
CURRENT FLOW
MAY 4, 2009
Figure 2. Main Page Displays
Figure 3. Key Pad Configuration
•
Units are factory set for "Clean Water" applications. For installations
with problem water (Iron, Manganese, turbidity, etc.) please refer to
Figure 12 on page 10 for "Problem Water" valve settings.
•
At the stated service flow rates, the pressure drop through these
devices will not exceed 15 psig.
•
The manufacturer reserves the right to make product improvements
which may deviate from the specifications and descriptions stated
herein, without obligation to change previously manufactured products
or to note the change.
CAPACITY
VOLUME REMAINING
1,350 GAL
1,125 GAL
REGENERATION
5 DAYS
TIME 2:00 AM
PEAK FLOW
1.5 GPM
5.8 GPM
*