Verify the contents
Check the contents of the SN6000 Fibre Channel
Switch power supply carton. The carton contains one
power supply.
Preparation
The power supplies are hot pluggable and
interchangeable. When removing or replacing a
power supply on an operating switch, be sure that the
Heartbeat LED is flashing once per second. This
indicates that the switch will continue operating
normally while the power supply is being removed or
replaced.
Figure 1 Observing the Heartbeat LED
1
1 Heartbeat LED (green)
Removing the failed power supply
1.
Unplug the power cord from the power supply.
2.
Using a cross-head screwdriver, loosen the two
knurled fasteners.
3.
Grasp the power supply handle and pull firmly
to disengage the modular connector.
4.
Remove the power supply from the bay.
Figure 2 Removing the failed power supply
1 Knurled fastener
1
2
1
2 Handle
Installing the new power supply
1.
Confirm that the new power supply air flow
direction is compatible with the old power
supply. The air flow direction is noted on the
part number label.
2.
With the AC receptacle on the right, slide the
power supply into the bay until it is firmly
seated.
3.
Secure the knurled fasteners by hand.
4.
Plug the power cord into the AC receptacle and
confirm that the air flow direction is correct.
Figure 3 Installing the new power supply