Aquatel D110 Gebrauchsanweisung - Seite 6
Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Monitor Aquatel D110 herunter. Aquatel D110 13 Seiten. Wireless level monitor
Auch für Aquatel D110: Gebrauchsanweisung (12 seiten)
6
Set Depth. For the D110 to determine the correct fluid levels, the depth of the
tank/cistern from
Menu", to access this menu see
7
Setting the Air Gap. Go to the
"Tank Unit Setup Menu" (refer to
once you enter this menu scroll
through to the "Air Gap" and
then using the arrow up and arrow
down buttons, select the required
air gap.
*Air gap: Distance between where
tank unit is installed and the maximum
fluid level)
100mm (min) – 1000mm (max)
3.93" (min) – 39.37" (max)
Ensuring Maximum Range
8
The D110 uses short range radio communications and works better with less
obstructions between Aquatel units. The more obstructions there are, the lower
the transmission range you will be able to achieve. For example, locating the
Display Unit by a window will give stronger communication signals than if it is
behind a concrete or metal wall. If you need to increase your radio signal strength
there are two antenna upgarde options available for purchase, the AQ930
Omni Booster Antenna giving up to 600m/2000' range LOS (line of sight) and the
AQ920-7 Yagi (Directional) Booster Antenna to give maximum working range
of up to 10km / 6 miles line of sight when used both ends. It is important to
follow all instructions and take good care when mounting antennas, this will
help to reduce risk of personal injury and provide the best working performance
of your new Aquatel Wireless Fluid Level Monitoring system. Detailed Antenna
mounting instructions can be downloaded from our webiste www.aquatel.co.nz.
must be input on the Display Unit via the "Tank unit Setup
3
.
10
) ,
10
– 5 –
Air Gap*