Panasonic WVBP554 - CCTV B/W CAMERA Betriebsanleitung - Seite 30
Blättern Sie online oder laden Sie pdf Betriebsanleitung für Digitalkamera Panasonic WVBP554 - CCTV B/W CAMERA herunter. Panasonic WVBP554 - CCTV B/W CAMERA 36 Seiten. Super dynamic dsp b/w cameras
Auch für Panasonic WVBP554 - CCTV B/W CAMERA: Betriebsanleitung (36 seiten), Spezifikationen (2 seiten)
(FINE adjustment can be made up to 22.5 degrees
by pressing
or
.)
Notes:
• When the "I" cursor reaches the "+" end, it
jumps back to " ". At the same time, COARSE
is incremented by one step to enable a contin-
uous adjustment. The reverse takes place
when the "I" cursor reaches the " " end.
• When
or
is kept pressed for a second
or longer, the "I" cursor moves faster.
• To reset COARSE and FINE to the values pre-
set at the factory, press
ously. COARSE and FINE adjustments are
preset at the factory to zero-crossing of the
AC line phase.
• If the AC line contains noise (spike noise,
etc.), the stability of the vertical phase of the
camera video output signal may be disturbed.
7. Motion Detector Setting (MOTION DET)
The motion detector detects the moving objects in the
scene by monitoring the brightness level changes. You
can select the level of sensitivity for motion detection.
When this camera is connected to a compatible intelli-
gent CCTV system, the camera transmits an alarm sig-
nal by multiplexing it with the video signal.
1. Move the cursor to the MOTION DET parameter
2. Press
** CAM SET UP **
CAMERA ID
ALC/ELC
SHUTTER
AGC
SENS UP
SYNC
MOTION DET
LENS DRIVE
or
simultane-
END
3. Move the cursor to MASK SET and press
4. Move the cursor to the ALARM parameter and
5. Move the cursor to DISPLAY MODE and press
-28-
and select ON.
. The MOTION DETECT menu appears
on the monitor screen.
OFF
ALC
LEVEL
---
ON
DISPLAY MODE
OFF
INT
ON
DC
MASK SET
SET UP ENABLE
RET
MASK SET menu has 48 masks. To set MASK SET,
proceed as described in steps 2 to 4 of "ALC
mode with SUPER-D OFF and ELC mode" on page
22.
select ON or OFF to set the alarm in the DISPLAY
MODE.
Note: When the system controller WV-RM70, WV-
CU550 or WV-CU550A is used with this
model, select OFF for ALARM.
to see the current setting. The masks that detect
the brightness changes start blinking.
** MOTION DETECT **
....I....
-
+
ALARM
ON
END
. The