aquatherm AT600 Betriebshandbuch für den Eigentümer - Seite 4

Blättern Sie online oder laden Sie pdf Betriebshandbuch für den Eigentümer für Wärmepumpe aquatherm AT600 herunter. aquatherm AT600 12 Seiten. Swimming pool & spa heat pumps
Auch für aquatherm AT600: Betriebshandbuch für den Eigentümer (12 seiten), Installationshandbuch (16 seiten)

"Digital Logic" Digital Control Panel Information
HEATER ON/OFF: To start the heater press this button and it's green light will come
on. To disable the heater press this button and its green light will go off.
THERMOSTAT BUTTONS: Pressing the + button will raise the set temperature.
Pressing the - button will lower the set temperature. When either button is pressed
the LED display will begin to flash. The flashing numbers indicate the thermostat
setting.
MODE SELECT BUTTONS-POOL or SPA: The heater has two thermostat modes
for two different desired temperature settings, one for pool mode and one for spa
mode. If you do not have a spa use the pool mode only. If you do have a spa, you
can connect two Jandy™ motorized plumbing valves. Therefore, when you select
either mode the motorized valves will turn to isolate the heater to either the pool or
spa. NOTE: There is a 30 second delay when switching pool/spa modes.
"OPTIONAL" WATER PUMP TIME CLOCK OVERRIDE OPERATION When the
T.C.O. button is set to the ON mode, the Time Clock Override feature is designed to
start the water pump whenever the pool requires heat. Once the pool is up to the set
temperature the heater will stop and then 5 minutes later the water pump will stop.
When this button is set to the OFF mode, the heater will operate only when the water
pump is running during the timed period set on the water pumps time clock.
NOTE: The time clock override works best if used during cooler weather conditions
where the pool is losing more than 8 to 10 degrees over night or when the pool is
being heated from "dead cold".
NOTE: If the time clock override starts the water pump and the thermostat does not
continue to call for heat for at least 5 minutes, the control will shut the water pump and
heater off. Thereafter, it will not re-attempt to start the water pump for 4 hours. This
4 hour delay can be bypassed by pressing the T.C.O. button off then back on.
NOTE: When the T.C.O. button is activated while in "spa mode" the water pump
will run the entire time you are in spa mode. When you switch back to pool mode
there will be a 5 minute delay before the water pump shuts off. The T.C.O. option
is built into the heater at the factory and can not be added later.
Page 4