3.
Press ▲ ▼ ◄ ► to move the cursor to
TIME and press ◄ ► to set the delay time for the
trigger output signal.
It is possible to delay the trigger output signal (12 V).
(Only available if Trigger OUTPUT item is selected.)
NOTE:
•
This trigger terminal output is used for control from
external equipment only.
You should not use it as the power source for external
equipment.
•
During start up and cooling off period, projector will not
accept the trigger input signal.
Please input the trigger signal only after it is in the
projection or standby mode.
•
The trigger control is not available to use for the
RS-232C command during the standby mode.
SLEEP
You can select the required duration of time and set
the off timer to turn off the power of the projector
automatically. 3 minutes before turn-off, the countdown
of minutes will be displayed in the lower right corner.
Press ◄ ► to cycle through the options.
OFF
60 MIN.
90 MIN.
120 MIN.
HIGH ALTITUDE MODE
If you use the projector at high elevation, the HIGH
ALTITUDE MODE setting need to be ON to set the fan
speed high. Press ◄ ► to select the required option.
OFF
The fan speed is low.
ON
The fan speed is high.
NOTE:
•
At 1 400 - 2 700 m (4 593 - 8 858 ft) above sea level,
the setting must be ON.
•
The loudness of fan noise depends on the
ALTITUDE MODE setting.
DELAY
LAMP POWER
You can adjust the power of the lamp to save on
electricity, prolong the lamp life and reduce the fun
noise.
NOTE:
•
VIERA LINK SETTINGS
You can set the VIERA Link settings. See "VIERA Link
Connection" on page 45.
TEST PATTERN
You can display the 5 different TEST PATTERN images
for your setting confirmation.
240 MIN.
Press the ENTER button to switch to the other patterns.
210 MIN.
LAMP RUNTIME
180 MIN.
You can check how long the lamp has been used.
NOTE:
150 MIN.
•
•
HIGH
Options
When higher luminance is
NORMAL
required.
ECO-MODE
When lower luminance is sufficient.
When no input signal is detected, the function is
disabled.
When
LAMP POWER is set to NORMAL; and LAMP
RUNTIME has reached 1 800 hours, LAMP RUNTIME
menu will inform the replacing time by flashing the red
and gray colour.
LAMP RUNTIME
is a relevant matter for lamp unit
replacement timing. See "Replacing the lamp unit" in
"Care and Replacement" of the operating instructions.
OPTION menu
Function
E
NGLISH - 41