Always have all utility lines and equipment marked by alocal service company prior to performing any work.
All electrical work shall be properly performed by a qualified electrician per all applicable codes. Failure to do so may result in severe bodily injury or death.
The BioBarrier
systems, including all electrical parts, are ETL (UL equivalent) certified for electrical safety. The control panel meets NEMA4X
®
standards for all weather use (not explosive or submerged environments).
1.
Examine wiring directions inside the supplied BIOBARRIER
2.
Confirm a dedicated breaker is supplied for the system in the building's master electrical panel.
3.
Make connections between the electro-mechanical devices of the system and BioBarrie
Always have all utility lines and equipment marked by a local service company prior to performing any
work. Failure to do so could result in severe bodily injury or death.
1. Attach the blue and yellow floats to the float tree line at the locations shown. The
be installed at the minimum height (or higher) shown in the picture for the single-stacked units. The
YELLOW switch MUST be installed no higher than 2 inches [5 cm] below the tank's inlet.
2. In the treatment tank, make connections to facilitate exiting of the wiring from the discharge pump and
the float switches. If a junction box is used inside the treatment tank manhole, waterproof connectors
must be used.
3. Insure the float wires are run in separate conduit from any power wires.
4. Mount the BioBarrier control panel in a location that is accesible to a service party, meets all code
requirements and prevents a voltage drop. The 110VAC panel requires a 15A breaker minimum. The
220VAC control requires a 20A breaker minimum.
5. Make connections inside the control panel as shown in the diagrams.

ELECTRICAL WIRING DIAGRAMS

Only the BioBarrier
0.5, 1.0, and 1.5 system diagrams are displayed here. Information for larger BioBarrier
®
BioMicrobics.
CONTROL PANEL & FLOAT REPLACEMENT
control panel (also found at the end of this Manual).
®
BLUE
switch MUST
control panel per the electrical diagram.
systems ships with the units or can be obtained from
®