Be sure to clean the inlet air filter on your compressor regularly. Wash dirty air filters
in soapy water. Replacement filters are available.
PA33 Packing List:
Description
2" Flex Hose
Membrane Air Diffuser
Tubing Clamps
100' Roll Tubing
_____' Additional Tubing
Packed By:
PA50 and PA60 Aeration Systems ...
These aeration systems come with a continuous
duty compressor, 200 feet of hose and two air dif-
fusers. Once the air diffuser is assembled and the
tubing is attached, you are ready to install the dif-
fuser. Always unroll the tubing completely before
installing the diffuser. The diffuser can be lowered
into your pond with a rope. Often a float, such as a
duck decoy or a milk jug, will be used so retrieval
of the diffuser is possible.
Assembly:
1.
Unpack all the parts. Compare parts with packing list below to ensure all parts
were received. If a shortage occurs, please notify us immediately.
2.
Screw the round rubber membrane diffuser into the PVC base. Fill base with
sand or small stone.
3.
Slide one end of the tubing onto the barbed adapter on the PVC base and
secure with a clamp (provided).
4.
Attach the 2' piece of flex pipe into the outlet side of the compressor.
5.
Unroll the entire roll of pipe. It is recommended that the pond diffuser be in-
stalled at this point. This will allow you to trim any unused pipe before attaching
to the pump. Once installed and trimmed, attach the other end of the tubing to
the flexible hose on the compressor.
6.
Connect the valved outlet assembly to the compressor.
7.
Connect the tubing to the flex hose on the compressor. Once the compressor
is running, you may have to adjust the valves to equal the air flow to each dif-
fuser. This corrects the difference in air flow caused by a difference in operating
depth and/or tubing lengths.
The PA50 and PA60 aeration systems are identical except for the compressor. The
PA60 compressor has a higher pressure rating for deeper water operation. All other
items and assembly are the same for these two kits. After one or two years of opera-
tion, you will possibly notice a sudden drop in air bubbles. This is a sign the com-
pressor needs new vanes. A rebuild kit is available to restore like-new performance.
Be sure to keep the air filter clean. Wash dirty air filters in soapy water. Replacement
filters are available.