Dickinson Newport - P9000 Installations- und Betriebshandbuch - Seite 7

Blättern Sie online oder laden Sie pdf Installations- und Betriebshandbuch für Innenkamin Dickinson Newport - P9000 herunter. Dickinson Newport - P9000 12 Seiten. Propane fireplace/heater

Step - 3
Step - 4
Step - 5
Step - 6
Step - 7
DIRECT VENT FITTING
Combustion Gases
Outside Air for Combustion
GAS SUPPLY AND HOOK-UP
THE HEATER OPERATES ONLY ON LOW PRESSURE LPG GAS (11"w/c)
If there is a propane fuel system installed a separate supply line must be supplied for the heater.
This line must be equipped with a low-pressure regulator (Dickinson Part No. 19-151)
Connect to the 3/8" flare connector of the heater with copper or an approved hose. During this
procedure some particles may get into the fuel line. These could block or restrict the small heater
orifice. BLOW OUT FUEL LINE PRIOR TO ATTACHING TO THE PROPANE SUPPLY AND
THE HEATER.
Disposable Propane Bottle
It is necessary to install a pressure regulator for gas supplied from a propane bottle.
type of installation we suggest using a Dickinson Low Pressure Kit (Part No. 19-150) This Kit
includes a pressure regulator (11 ins W/C) and a mounting kit. The kit must be mounted
outside.
These are available in 10 ft ( 3m) (Part No. 19-100-10) or 20 ft (6m)(Part No. 19-100-20)
AFTER GAS HOOK-UP AND BEFORE LIGHTING THE HEATER
Attach the dress ring on the inside, and on the underside, of the fitting with the 4
S/S screws supplied. Make sure that the opening lines up with the underside of
the thru-deck or the pipe will not fit correctly.
Install the flexible pipe on the heater.
Make whatever bends are necessary in the flexible pipe and push into the thru-
fitting.
Secure the heater in position by attaching the back mounting plate.
Using the screw pilot holes in the outer pipe of the thru-fitting drill two 1/8"
holes in the flexible pipe and install sheet metal screws to secure.
Deck
A Dickinson AGA/CGA propane hose can be used to connect this Kit to the heater.
www.ahoycaptain.com
For this
7