Alpha Fan AX70-5B/56 Gebrauchsanweisung - Seite 7
Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Fan Alpha Fan AX70-5B/56 herunter. Alpha Fan AX70-5B/56 8 Seiten.
POWER SUPPLY CONNECTION
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER
SWITCH OR REGULATOR.
Regulator
Dimmer Switch
Double Pole
Power
Switch
Supply
Single Pole
Switch
11
CIRCUIT DIAGRAM
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER
SWITCH OR REGULATOR.
DC
Motor
Neutral (Blue)
Live (Brown)
Earth (Green/Yellow)
Power Supply
220V-240V - 50Hz
MAINTENANCE
Due to the fan's natural movement, connections may get loose after period of usage. To ensure a proper
and safety usage, it is highly recommended to inspect and tighten all connections every 6 months.
Cleaning
Cleaning your fan periodically will prolong its new appearance. Basic cleaning procedures
are as follows :
1. Use only water and mild soap. Do not use solvents, corrosive or acidic solution.
2. Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will
scratch the surface.
3. Do not bent the blades while cleaning. At the event where blades are bent or damage,
order new set of blades from service center or dealer shop.
4. There is no need to oil the fan.
W
ANT
V
U
MAIN PCB
Blue
N
Brown
L
Green/Yellow
E
12