dicodes Dani Extreme V2 Kurzanleitung - Seite 2

Blättern Sie online oder laden Sie pdf Kurzanleitung für Elektronische Zigaretten dicodes Dani Extreme V2 herunter. dicodes Dani Extreme V2 2 Seiten.

Errors
Temp.-Coefficient Down
Power Limit
Heater Protection Setting
Power Boost Setting
Display
Vaping
H
s
e
Luminosity
Time
e
t
"
a
a
(
Switch Off
Energy
n
E
t
Time
(Joule=Ws)
d
x
e
a
t
Power On
r
Battery
r
e
Clicks
Capacitance
C
d
n
o
Menu On
Reset Counters
(
d
n
Clicks
0
e
t
Total Lifetime
,
d
Click
Puffs
r
p
F
Speed
o
o
u
Total Lifetime
l
w
n
Half
Vaping
T
e
Wattage
c
h
r
t
Temperature
e
s
i
Unit (°C/°F)
m
e
o
o
t
n
Automatic
d
t
s
Calibration on/off
c
i
M
Display
a
n
e
n
g
Orientation
n
b
)
u
Expert
e
o
)
(*1) This measurement is important for temperature controlled vaping. Make sure, that the coil has cooled down
Mode
u
r
e
before performing the reference measurement. Otherwise the temperature display and control will have an offset.
s
t
n
(Re)set to
E.g.: If done at 40°C coil temperature the actual temperature will be 240°C instead of selected 220°C.
e
e
a
Defaults
d
m
b
i
p
l
n
e
e
5
r
d
o
a
,
p
t
a
e
u
d
r
r
d
a
e
i
t
c
t
i
o
i
o
n
o
n
t
n
m
r
a
o
o
l
d
l
o
e
l
p
s
e
e
.
d
r
T
v
a
h
a
t
e
p
i
d
i
o
e
n
n
f
g
m
a
(
o
u
1
d
l
)
e
t
.
s
o
W
a
p
i
r
e
t
e
r
h
H
a
t
e
t
h
a
i
e
t
o
"
e
n
E
r
i
x
P
s
p
r
e
e
o
i
r
t
t
t
e
h
M
c
e
o
t
r
d
i
on (2), Power Boost (3), and Bypass (4, mechanical mod). With Expert Mode
disabled, the menu options 2-4 are unavailable.
Switch Off Device
Beside the Auto-Power-Off feature, the user can manually turn off the device. It
is recommended that the user turn off the device before replacing the battery,
because then the statistic counters are saved. Otherwise the
changes since the
last power up are lost.
Extended Functions Menu
The Extended Functions Menu has three sub-menus:
Heater Menu
Settings related to the heater or coil
Mod Menu
Settings related to the individual usage and appearance
Value Menu
Provides several statistics of vaping
Error Messages
If an error occurs, the mod directly jumps to the error menu and
displays the error number and a mnemonic (short-term) description.
Important Errors are (for further information, please refer to manual):
1 ChkAtom: No atomizer detected or open coil.
(*1 ) The temperature coefficient depends on the type of wire material, and resistance range 100 to 650: 320=dicodes-
2 TempRef: A problem during the temperature reference measurement occurred
wire, 620=Nickel
about 105=Stainless Steel, 350=Titanium (fire danger), 480=Tungsten (Wolfram).
4 OverCur: Short on coil or coil breakdown (open)
Value to set = Literature-value*10E5 K. Example Ni 6.2E-3*1/K *10E5*K =620.
(*2 ) Setting 1 (fastest) as 2 but without animation (visual shift effect), setting 5 (slowest) as 4, but without
fast auto-repeat.
(*3 ) Auto calibration is performed, when MOD is switched on, or when atomizer was removed and new atomizer
is applied (when MOD is already on).
(*4) For more detailed information about the menu, setting options and working principles of different
modes, please refer to the manual.
Mod Disposal
The symbol below indicates that this product should not be treated as house- hold
waste, but according to WEEE as electrical waste (e-waste). Thank You!
dicodes GmbH Friedrich
der Große 70 DE-44628
Herne Germany
Phone: +49 2323 1463635
Errors excepted. Subject to changes without prior notice.
c copyrights dicodes GmbH, Germany, no unauthorized reprint. 19.05.2015 dicodes DaniV2 short form, ENG, revision 1.1