EPC EPC9509 Schnellstart-Handbuch - Seite 6
Blättern Sie online oder laden Sie pdf Schnellstart-Handbuch für Verstärken EPC EPC9509 herunter. EPC EPC9509 12 Seiten. 6.78 mhz, zvs class-d wireless power amplifier
QUICK START GUIDE
V
AMP
0
Partial
ZVS
Shoot-
through
PAGE 6 |
Figure 4: Proper measurement of the switch nodes using the hole and ground post
Q1 turn-o
Q2 turn-on
ZVS
ZVS + Diode
Conduction
Figure 5: ZVS timing diagrams
| EPC – EFFICIENT POWER CONVERSION CORPORATION |
Place probe tip
in large via
V
AMP
0
Partial
time
ZVS
Shoot-
through
Demonstration System EPC9509
Do not use
probe ground
lead
Minimize
loop
Q2 turn-o
Q1 turn-on
ZVS
ZVS + Diode
Conduction
WWW.EPC-CO.COM
Ground
probe
against
post
time
| COPYRIGHT 2015