Epcom EP20-TB-2600 Benutzerhandbuch - Seite 9

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Verstärken Epcom EP20-TB-2600 herunter. Epcom EP20-TB-2600 12 Seiten. Triple band signal amplifier

Epcom EP20-TB-2600 Benutzerhandbuch
Items
Power Consumption
RF Connector
I/O Impedance
Environment Class
Operating Humidity
Operating Temperature
Heat Dissipation
Size
Weight

Installation Guides

a. Installation Site Requirements
1) The amplifier should be installed in a place with stable and independent power supply.
2) The amplifier should be installed in the space without corrosive gas, smokes and leaky
liquids.
3) The amplifier had better be installed on the wall that is ventilated, waterproof, lightning-
proof and without sunshine.
4) The height of the installation site should be safe and easy for cabling, maintaining & good
for heat dissipation.
b. Installation Tools
No.
Items
1
Impact drill
2
Wrench
3
Mobile phone for testing
4
Multimeter
5
Screwdriver
6
Waterproof tape
c. Installation Steps
1) Find a site with the strongest signal for the outdoor antenna with your mobile phone by the
way below. And temporarily install the outdoor antenna. The direction of the outdoor antenna
should be towards to nearest base station.
iPhone: Dial *3001#12345#*, then press call. Select "Serving Cell Measurement" to see the
RSRP or RSSI.
Android: Setting→ About Phone → Status or Network → Signal Strength or Network Type
Uplink
Quantity
1
Drill holes on wall, <self-provided>
1
Reinforce the interface connection, <self-provided>
1
Test installation effectiveness, <self-provided>
1
Test voltage and wiring connection, <self-provided>
1
Tighten or fasten the device, <self-provided>
Prevent liquid from leaking into the feeder
A few
interface, <self-provided>
8
Downlink
< 25 W
N-Female
50Ω
IP40, for indoor
< 90%
-10℃ ~ +50℃
Conventional
L206xW140xH37mm
≤ 3Kg
Remarks