Dictator DICTAMAT 50 WS-MFL Technisches Handbuch - Seite 4

Blättern Sie online oder laden Sie pdf Technisches Handbuch für Türöffnungssystem Dictator DICTAMAT 50 WS-MFL herunter. Dictator DICTAMAT 50 WS-MFL 17 Seiten.

Technical Manual
DICTAMAT 50 WS-MFL
1) Determining the
Mounting Positions
Spring rope pulley
Bracket with
supporting rope
tensioner and
clamp piece for
WS 6 wire rope
Page D50WS-MFLHB.04
C) Installation of the DICTAMAT 50 WS-MFL
The spring rope pulley of the DICTAMAT 50 WS-MFL is mounted in the
CLOSED position of the sliding door.
Radial damper LD with attachment for wire rope
Wire rope WS
and
supporting rope
CLOSE
Only the wire rope and the supporting rope hold the radial damper LD
50 WS with freewheel carrier. It is not fixed to the door!
IMPORTANT: The wire rope and the supporting rope have to position
the freewheel carrier in such a way that with one side it can push with
the buffer the door leaf and on the other side, when the door is open,
the complete surface of the magnet adheres to the counter
plate (see ill. 7).
Door
The attachment on the radial damper for guiding the wire rope can be
turned according to the required damping direction (see point C/2d).
IMPORTANT: The bracket with the tensioning device for the supporting
rope and the clamp piece for the wire rope as well as the bracket with
the wire rope tensioner and the holder for the supporting rope have to
be mounted so that the wire rope and the supporting rope run exactly
in a straight line (see ill. 8).
© DICTATOR Technik GmbH • Gutenbergstr. 9 • 86356 Neusäß • Germany
Tel. +49(0)821-24673-0 • Fax +49(0)821-24673-90 • E-mail [email protected] • 201906
in freewheel carrier with counter plate
Bracket with magnet, wire
rope tensioner and holder
for the supporting rope
Ill. 6
Ill. 7
Ill. 8